Model reference
LG LMNH126LRL0
Air Conditioner
2 documents13 error codes18 service modes
Available documentation
Service Manual
- Multi Type Air Conditioner SERVICE MANUAL160 pg
- Multi Type Air Conditioner SERVICE MANUAL157 pg
MyPros+ Max
Diagnose your LG LMNH126LRL0.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (13)
CodeMeaning
01Indoor room thermistor error (open/short circuit).02Indoor inlet pipe thermistor error (open/short circuit).03Wired remote controller communication error (open/short/wrong connection).04Drain pump / float switch error (float switch open, normally should be short).05Communication error between indoor and outdoor unit (indoor side display).06Indoor outlet pipe thermistor error (open/short circuit).33Discharge pipe temperature high (compressor discharge sensor temperature high).44Outdoor air thermistor error (open/short circuit).45Condenser pipe thermistor error (open/short circuit).47Constant compressor discharge pipe thermistor error (open/short circuit).51Capacity error (over capacity combination of indoor units).53Communication error between indoor and outdoor unit (outdoor side display).54Phase error on outdoor unit 3-phase power supply.Service modes (18)
- Address Monitoring (Wireless Remote Controller)Press Chaos Swing (6) and Reset (13) keys simultaneously to enter Address Monitoring Mode.
- address_monitoring_wirelessPress Chaos Swing (6) and Reset (13) keys simultaneously to enter Address Monitoring Mode
- address_setting_wired1) Press Program (13) and Set/Clear (16) keys simultaneously for more than 3 seconds to enter…
- address_setting_wired_remocon["Press Program (key 13) and Set/Clear (key 16) simultaneously for more than 3 seconds to enter…
- address_setting_wireless1) Press Jet Cool (5) and Reset (13) keys simultaneously for more than 3 seconds to enter Address…
- address_setting_wireless_remocon["Press Jet Cool (key 5) and Reset (key 13) simultaneously for more than 3 seconds to enter Address…
- ESP (External Static Pressure) Setting (Duct Type)1
- esp_setting["Push the On/Off button to start the unit.","Push the Timer and Wind button simultaneously for…
- Forced Operation (Cassette Type)Press the button for 2 seconds to start forced operation.
- Forced Operation (Slide Switch)Switch the slide switch on the main indoor unit to the forced operation position while power is on…
- forced_operation["Locate the forced operation slide switch on the main unit.","Switch the slide switch from remote…
- forced_operation_cassettePress the forced operation button on the cassette type unit for 2 seconds.
- Indoor Unit Address Setting (Wired Remote Controller)1
- Indoor Unit Address Setting (Wireless Remote Controller)1
- Test Run (Cassette Type)Press the button for 5 seconds to start the test run.
- Test Run (Room/Split Type)Press the timer cancel button five times continuously on the remote controller.
- test_run_cassettePress the forced operation button on the cassette type unit for 5 seconds.
- test_run_room_typePress the Timer Cancel button five times continuously on the room type remote controller.
Full entry steps, exit procedures, and test sequences are available in Max.