Model reference
Maytag MEDZ600TW2
Dryer
11 documents8 error codes3 service modes
Available documentation
Tech Sheet
- Tech Sheet - W10117402A12 pg
- TECH SHEET - W10117402 - Rev A12 pg
Service Flash
- Dry Time Display Appears to Jump or Stall4 pg
Tech Tip
- Instruction Sheet2 pg
- Instruction Sheet - 8574875 - Rev A - Special Handling4 pg
- Instruction Sheet - W10318609- Rev A - Special Handling7 pg
- Instruction Sheet2 pg
- Instruction Sheet12 pg
Installation Guide
- Installation Instructions16 pg
Other
- ML 9 Maytag Epic Z Electronic Gas Electric Dryer96 pg
- Service Pointer 81787334 pg
MyPros+ Max
Diagnose your Maytag MEDZ600TW2.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (8)
CodeMeaning
F-01Primary control failure.F-02Stuck button or user interface mismatch (only appears in diagnostic test mode).F-22Exhaust thermistor is open.F-23Exhaust thermistor is shorted.F-26Motor drive system failure.F-28Moisture sensor strip is open (only appears in diagnostic test mode).F-29Moisture sensor strip is shorted (only appears in diagnostic test mode).PFPower failure occurred while the dryer was running.Service modes (3)
- Diagnostic Test Mode["Ensure the dryer is in standby mode (plugged in with all indicators off, or with only the Dry…
- Dryness Level Adjustment Mode["Activate the diagnostic test mode and advance past saved fault codes.","In diagnostic test mode…
- Saved Fault Codes Review["Enter Diagnostic Test Mode.","If saved fault codes exist, the most recent fault code is…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Maytag dryer models
78,000+ service manuals · 160,000+ error codes · 55+ brands