Error codes (117)

View all 117 error codes
4dDoor latch not operating properly.4d11Door switch not closed when door is locked.4d12Door switch position failure4d21No cooling fan rotation detected.4d22No Reverse Airflow Fan rotation (no/low RPM) on lower oven cavity.4d31Cooling fan is on when it should be de-energized.4d32Reverse Airflow Fan state error4d41Cooling fan overspeed condition detected.4d42High Reverse Airflow Fan rotation (high RPM) on lower oven cavity.4d51Door switch circuit fault.4d52Door switch circuit failure51BAKE/BROIL range over temperature condition.52CLEAN range over temperature condition.6CEEPROM communications error (internal control error).7CEEPROM communications error (internal control error).8CEEPROM communications error (internal control error).9dLatch error during CLEAN cycle.9d11Door latch will not lock.9d12Door latch will not lock on lower oven cavity9d21Door latch will not unlock.9d22Door latch will not unlock on lower oven cavity9d31Door latch reports both locked and unlocked simultaneously.9d32Door latch both locked and unlocked simultaneously on lower ovenE61Humidity sensor open (unplugged, wiring, or smart board failure).E62Humidity sensor shorted (unplugged, wiring, or smart board failure).F0E1Load detected in drum during Clean Washer cycle.F0E2Excessive suds detected in washer; washer is running a suds reduction routine.F0E4High temperature error during wash cycle.F0E5Off balance load detected.F1Internal board failure (LCC 90/95). Corresponds to F1E0, F1E1, F1E2 on LCC…F1-E0EEPROM communication error.F1-E1Upper RTD uncalibrated.F1-E2Lower RTD uncalibrated.F1-E5Sensor usage out of range.F1-E7PCB thermistor/sensor open or shorted.F1-E9WIDE queue full.F1E0Internal board failure / A/D Error.F1E1Internal board failure / A/D Error.F1E2Internal board failure / A/D Error.F2Shorted key (LCC 90/95)F2-E0Keypad disconnected.F2-E1Stuck key.F2-E2Stuck key.F2E0Shorted key.F3Oven sensor opened or shorted (LCC 90/95)F3-E0Main oven temperature sensor open or shorted (upper oven).F3-E1Main oven temperature sensor open or shorted (lower oven).F3E0Oven sensor opened.F3E1Oven sensor shorted.F3E2BAKE/BROIL range over temperature.F3E3CLEAN range over temperature.F3E4Deli compartment (Z2) thermistor short or open circuit.F3E5Crisper (Z3) thermistor short or open circuit.F3E6Accelerometer error.F4E1Wash heater relay error or no feedback signal; ACU cannot detect temperature…F4E2Heating timeout.F5Door and door position switches do not agree or door latch not operating in…F5-E0Door and door position switch(es) do not agree during Clean mode.F5-E1Door latch not operating during Clean mode.F5E0Door and door position switches do not agree (Clean mode).F5E1Door latch not operating (Clean mode).F5E2Door and door position switches do not agree (Clean mode).F5E3Door unlock failure.F5E4Door not open error.F6-E0Lost communications.F6-E1Over temperature during cook mode (runaway temp).F6-E2Over temperature during clean mode (runaway temp).F6-E3Over temperature in warming drawer (runaway temp).F6E1No communication from the HMI detected by ACU.F6E2No communication from the ACU detected by the HMI.F6E3No communication from the MCU detected by the ACU.F7E2MC/MCU over temperature error or over current error/internal failure.F7E8MC/Motor over temperature error.F7E9Motor will not turn (locked rotor).F7EAMotor disconnected error (also displayed as F7E10).F7ECMC/MCU overload (also displayed as F7E12).F8E1Long fill error (may also display as Lo Flo).F8E3Overflow condition detected.F9Miswired house or miswired range (LCC 90/95)F9-E0Product is mis-wired.F9E0Miswired house or miswired range.F9E1Long drain error.FCE0Communication between the Human Machine Interface and Wi-Fi Module has not been…FDE0Ice maker tray thermistor short or open circuit.FDEAIce Maker Jammed (cannot find Homing or end of harvest location).OPOpen circuit detected on thermistor.SHShort circuit detected on thermistor.

Service modes (38)

  • Control LockoutPress the Back and Setup pads simultaneously for 5 seconds to lock.
  • Control Reset1
  • Demo Mode1
  • Diagnostic Code Display Mode (H1 Controls)Press and hold AUTOSET pad for 3 seconds at power-up.
  • Diagnostic Code Display Mode (H3 Controls)Press and hold Upper Cancel and Timer for 3 to 5 seconds within 5 minutes of power up.
  • Diagnostic Code Display Mode (NSC Controls)Press and hold the More + pad for 3 to 5 seconds when powering up the unit (within 60 seconds of…
  • Diagnostics ModePress CANCEL > CANCEL > START within a 5-second period. Display shows 'tSt' (3-digit LCC 90/95) or…
  • Diagnostics Test Mode (Relay Checks)While in Diagnostics Mode
  • Display Test1
  • Engineering Mode1
  • Fault/Error Code DisplayEnter Service Diagnostic Mode
  • Faults (Error Code Review/Clear)1
  • Faults Access1
  • Faults Access (EOC III Controls)1
  • Human-Machine Interface TestFrom Service Diagnostic Mode
  • One-Watt Standby Mode (NSC Controls)Press and hold Cancel and Less
  • Quick Diagnostic TestFrom Service Diagnostic Mode
  • Quick Test Mode (EOC III Controls)1
  • Quick Test Mode (EOC III)1
  • Quick Test Mode (H1 Controls - Convection Model)1
  • Quick Test Mode (H1 Controls - Non-Convection Model)1
  • Quick Test Mode (H2/H2.5 Controls)1
  • Quick Test Mode (H3 Controls)1
  • Quick Test Mode (M1/M2 Controls)1
  • Quick Test Mode (NSC Non-Self Clean Controls)1
  • Semi Automatic Test1
  • Sensor Test (Quick Test)["Press and hold AUTO DEFROST and SENSOR REHEAT simultaneously.","Observe diagnostic number in…
  • Service Diagnostic Mode1. Ensure washer is in standby mode (plugged in with all indicators off). 2. Wait 30 seconds after…
  • Service Diagnostics Mode["Press the pulsing JennAir logo to wake up the UI.","Press the middle zone key.","Press CONNECT…
  • Service Mode1
  • Service Mode (EOC III Controls)1
  • Software Version DisplayFrom Service Diagnostic Mode
  • Software Versions Access1
  • Temperature Adjustment ModeStep 1
  • Test Mode (Manual Relay Activation)1
  • Test Mode (UH Controls)1
  • Usage1
  • Version1

Full entry steps, exit procedures, and test sequences are available in Max.

75,000+ service documents · 20,000+ error codes · 100+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax