Maytag GGG390LXQ00
Range
3 documents36 error codes7 service modes
Available documentation
Tech Sheet
- techsheet w10311749 reva32 pg
Service Flash
- Technical Service Pointer - W10418467 (Gas Smell)3 pg
- Moisture Escaping from Upper Oven3 pg
MyPros+ Max
Diagnose your Maytag GGG390LXQ00.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (36)
CodeMeaning
E0 F1EEPROM communication error.E0 F2Keypad disconnected.E0 F3Main oven temperature sensor open or shorted (upper cavity).E0 F5Door and latch switches do not agree during Clean mode.E0 F6Lost communications.E0 F9Product is mis-wired.E1 F1Upper RTD uncalibrated.E1 F2Stuck key.E1 F3Main oven temperature sensor open or shorted (lower cavity).E1 F5Door latch not operating during Clean mode.E1 F6Over temperature during cook mode (runaway temp).E2 F1Lower RTD uncalibrated.E2 F2Stuck key.E2 F6Over temperature during clean mode (runaway temp).E3 F6Over temperature in warming drawer (runaway temp).E5 F1Sensor usage out of range.E7 F1PCB thermistor/sensor open or shorted.E9 F1WIDE queue full.F1 E0EEPROM communication error.F1 E1Upper RTD (resistance temperature detector) uncalibrated.F1 E2Lower RTD uncalibrated.F1 E5Sensor usage out of range.F1 E7PCB thermistor/sensor open or shorted.F1 E9WIDE queue full.F2 E0Keypad disconnected.F2 E1Stuck key.F2 E2Stuck key.F3 E0Main oven temperature sensor open or shorted (upper cavity).F3 E1Main oven temperature sensor open or shorted (lower cavity).F5 E0Door and latch switches do not agree during Clean mode.View all 36 error codes
Service modes (7)
- Diagnostics ModePress CANCEL > CANCEL > START within 5 seconds.
- Diagnostics Mode (includes Semi Automatic Test)["Press CANCEL, then CANCEL, then START within 5 seconds.","If control does not enter Diagnostics…
- Faults (view stored fault codes)1
- Semi Automatic Test1
- Semi Automatic Test Mode["Enter Diagnostics Mode first (CANCEL>CANCEL>START within 5 seconds).","Press TEMP/TIME '+' or '-'…
- Temperature Calibration["Press SETTINGS/OPTIONS until 'Temp Calib' is highlighted.","Follow instructions to see the…
- Test Mode["Enter Diagnostics Mode first (CANCEL>CANCEL>START within 5 seconds).","Press TEMP/TIME '+' or '-'…
Full entry steps, exit procedures, and test sequences are available in Max.