Model reference
Maytag JDS9860BCP
Range
4 documents18 error codes4 service modes
Available documentation
Tech Sheet
- Tech Sheet - 16026095F (FR)13 pg
- Technical Information—Dual Fuel Slide-In Range11 pg
Service Flash
- Service Pointer - 8178755 (Two Burner Cartridge)2 pg
Other
- 81787551 pg
MyPros+ Max
Diagnose your Maytag JDS9860BCP.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (18)
CodeMeaning
F0-0No error.F1-1Oven temperature exceeded 650°F (343°C) in bake mode.F1-3Oven temperature exceeded 950°F (510°C) during a clean cycle.F1-5Cancel key is not responding.F1-7Membrane disconnected.F1-8Key (keypad) shorted in membrane switch.F1-9Internal control communication errors.F1-ALock/unlock switch status does not pass to the control.F1-COven door switch status does not pass to the control.F1-EControl not calibrated.F1-FJumper not removed from the circuit board.F1-HEEPROM error.F1-NIncorrect internal voltage of the slave micro.F3-1Oven temperature sensor open or shorted.F8Meat probe shorted.F9-1Oven door will not lock.F9-2Oven door will not unlock.F9-3Oven door status is both locked and unlocked.Service modes (4)
- Factory Default Options Change1
- Quick Test (Quick Check Mode)1
- Quick Test ModePress and hold Cancel and Broil pads simultaneously for 3 seconds at power-up, or within 5 minutes…
- Setup Options (Default Configuration)Press Setup Options and the desired pad simultaneously (see options table)
Full entry steps, exit procedures, and test sequences are available in Max.