Model reference
Maytag MER8800FZ2
Range
8 documents37 error codes28 service modes
Available documentation
Tech Sheet
- Tech Sheet - W11393920 - Rev A8 pg
- Service Tech Sheet W11393918A2 pg
- Wiring Diagram - W11393928 - Rev A2 pg
- Tech Sheet - W10667169 - Rev C8 pg
Service Manual
- SERVICE MANUAL - Whirlpool®, Maytag®, KitchenAid®, Kenmore®, JennAir®, IKEA®, and Amana® Ranges104 pg
- Technical Manual - Cooking Surface Temperature Limits12 pg
Quick Reference
- Quick Start Guide1 pg
- Freestanding Electric Range Control Guide8 pg
MyPros+ Max
Diagnose your Maytag MER8800FZ2.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (37)
CodeMeaning
F1EEPROM communication error or internal control failure (Maxwell/MRC control).F1-E0EEPROM communication error.F1-E5Sensor out of range.F1-E7PCB thermistor open or shorted.F1E0EEPROM communication error.F1E1A/D error (LCC/LCX control).F1E2A/D error (LCC/LCX control).F1E5Sensor out of range.F1E7PCB thermistor open or shorted.F2Keypad disconnected, stuck key, or cancel key error (Maxwell/MRC control).F2-E0Keypad disconnected.F2-E1Stuck key.F2-E2Cancel key error.F2E0Keypad disconnected.F2E1Stuck key.F2E2Cancel key error.F3-E0Main oven sensor open or shorted.F3-E2Warming drawer sensor open or shorted.F3E0Main oven sensor open or shorted.F3E1Oven sensor shorted (LCC/LCX control).F3E2Warming drawer sensor open or shorted.F3E3Clean range over temperature (LCC/LCX control).F5-E0Door and switches do not agree (Clean modeF5E0Door and switches do not agree (Clean modeF5E1Door latch not operating during Clean mode (LCC/LCX control).F5E2Door and door position switches do not agree during Clean mode (LCC/LCX…F6-E1Over temperature during cook mode.F6-E2Over temperature during clean mode.F6-E3Over temperature in warming drawer.F6E0Oven User Interface lost communication between UI and ACU (Indigo control).View all 37 error codes
F6E1Over temperature during cook mode.F6E2Over temperature during clean mode.F6E3Over temperature in warming drawer.F6E4Oven User Interface UI and ACU state status mismatch (Indigo control).F8E0Cooling fan speed too lowF8E2Cooling fan speed too highF9E0Mis-wired house or range (Maxwell/MRC control).
Service modes (28)
- Auto TestEnter Diagnostics Mode (CANCEL > CANCEL > START), then press the 'up' arrow, '+' key, or '3' key to…
- Auto Test - Maxwell/MRC Controls["Enter Diagnostics Mode (CANCEL>CANCEL>START)","Press the 'up' arrow, '+' key, or '3' key to…
- Auto Test (Maxwell/MRC Controls)1
- Component Activation (Indigo Controls)From Diagnostics Menu, select Component Activation
- Diagnostics ModePress CANCEL > CANCEL > START within 5 seconds.
- Diagnostics Mode - Indigo Controls (Option 1)["Press HOME>FAVORITES>LIGHT (repeat this sequence three times in a row)","The warning will be…
- Diagnostics Mode - Indigo Controls (Option 2)["Press TOOLS>INFO>SERVICE AND SUPPORT","Press the Diagnostics button for 1 minute","Press…
- Diagnostics Mode - LCC/LCX Controls["Press CANCEL","Press CANCEL","Press START (all within a 5-second period)","Initial display shows…
- Diagnostics Mode - Maxwell/MRC Controls["Press CANCEL","Press CANCEL","Press START (all within quick succession)","Display shows 'TEST ON'…
- Diagnostics Mode (Auto Test)1
- Diagnostics Mode (Indigo Controls) - Option 1Press HOME > FAVORITES > LIGHT, repeat three times in a row
- Diagnostics Mode (Indigo Controls) - Option 2Press TOOLS > INFO > SERVICE AND SUPPORT
- Diagnostics Mode (LCC/LCX Controls)Press CANCEL > CANCEL > START within a 5-second period. Scroll through settings with up arrow…
- Diagnostics Mode (Maxwell/MRC Controls)Press CANCEL > CANCEL > START within 5 seconds
- Diagnostics Mode (MRC Control)Press CANCEL > CANCEL > START
- Diagnostics Test Mode Relay Checks (LCC/LCX Controls)While in Diagnostics Mode
- DISPLAYEnter Diagnostics Mode (CANCEL > CANCEL > START), scroll to service mode 5 'DISPLAY'.
- ENG MODEEnter Diagnostics Mode (CANCEL > CANCEL > START), scroll to service mode 2 'ENG MODE'
- FAULTSEnter Diagnostics Mode (CANCEL > CANCEL > START), scroll to service mode 7 'FAULTS'.
- RELAY USAGEEnter Diagnostics Mode (CANCEL > CANCEL > START), scroll to service mode 8 'RELAY USAGE'.
- Service Modes - Maxwell/MRC Controls (TEST ON, USAGE, ENG MODE, TEST MODE, VERSION, DISPLAY, FAULTS, EXTERNAL FAULTS, RELAY USAGE, AUTO TEST)["Press CANCEL>CANCEL>START to enter Service Mode","Use up arrow/+ key/3 key to scroll through…
- Service Modes Menu (Maxwell/MRC Controls)Press CANCEL>CANCEL>START. Scroll through modes using up arrow/'+'/3 key
- Temperature AdjustmentPress OVEN LIGHT for 5 seconds (current offset shown in display, or 0° if no offset)
- TEST MODEEnter Diagnostics Mode (CANCEL > CANCEL > START), scroll to service mode 3 'TEST MODE'
- TEST ON - Relay Checks (Maxwell/MRC Controls)From Diagnostics Mode (CANCEL>CANCEL>START), at TEST ON display
- TEST ON (Relay Checks)Upon entering Diagnostics Mode (CANCEL > CANCEL > START), 'TEST ON' is displayed. Press specific…
- USAGEEnter Diagnostics Mode (CANCEL > CANCEL > START), scroll to service mode 1 'USAGE'.
- VERSIONEnter Diagnostics Mode (CANCEL > CANCEL > START), scroll to service mode 4 'VERSION'.
Full entry steps, exit procedures, and test sequences are available in Max.
Related Maytag range models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass