Model reference
Maytag MET8720DH01
Range
6 documents50 error codes15 service modes
Available documentation
Tech Sheet
- Tech Sheet - W10595635 - Rev A32 pg
- Tech Sheet64 pg
- Tech Sheet64 pg
- Tech Sheet - W10647745 - Rev B64 pg
Installation Guide
- Installation Instructions20 pg
- Instruction Sheet1 pg
MyPros+ Max
Diagnose your Maytag MET8720DH01.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (50)
CodeMeaning
C-81Induction cooktop over temperature (Type 2 failure).C-82Induction cooktop over temperature (Type 2 failure).C-83Induction cooktop temperature sensor stuck (Type 2 failure).F-12Induction cooktop coil under current (Type 1 failure, affects only one burner).F-21Induction cooktop supply power frequency error (Type 2 failure, affects all…F-25Stuck fan on Induction Power System (IPS)F-36Induction cooktop temperature sensor is not working (Type 1 failure).F-37Induction cooktop temperature sensor is not working (Type 1 failure).F-40Induction Power System (IPS) failure (Type 1 or Type 2).F-42Induction cooktop power supply issue (Type 2 failure).F-43Induction cooktop under voltage (Type 2 failure).F-47Power supply from Induction Power Control (IPC) to User Interface is missing…F-56Wrong or invalid configuration (Type 3 failure, disables entire cooktop).F-58Wrong or invalid configuration (Type 2 failure).F-60UI does not work (Type 3 failure, disables entire cooktop).F1-E0EEPROM communication error (internal).F1-E1Upper RTD uncalibrated (internal).F1-E2Lower RTD uncalibrated (internal).F1-E5Sensor usage out of range (internal).F1-E7PCB thermistor/sensor open or shorted.F1-E9WIDE queue full.F1E0EEPROM Communication ErrorF1E1Upper RTD UncalibratedF1E2Lower RTD UncalibratedF1E5Sensor Usage Out of RangeF1E7PCB Thermistor Open or ShortedF1E9WIDE Queue FullF2 E1Stuck key detected on keypad.F2 E2Stuck key detected on keypad.F2-E0Keypad disconnected from oven control.View all 50 error codes
F2E0Keypad DisconnectedF2E1Stuck KeypadF2E2Cancel or Off Key Error/Warming Zone Off Keypad ErrorF3 E0Upper oven main temperature sensor open or shorted.F3-E1Lower oven main temperature sensor open or shorted.F3E0Main Sensor Open or Shorted (Upper)F3E1Main Sensor Open or Shorted (Lower)F5-E0Door and door position switch(es) do not agree during Clean mode.F5-E1Door latch not operating during Clean mode.F5E0Door and Latch Switches Do Not AgreeF5E1Latch Not OperatingF6 E0Lost communications between control components.F6 E1Over temperature during cook mode (runaway temp).F6 E3Over temperature in warming drawer (runaway temp).F6-E2Over temperature during clean mode (runaway temp).F6E0Lost WIDE CommunicationF6E1Over Temp CookF6E2Over Temp CleanF9-E0Product is mis-wired.F9E0Miswired
Service modes (15)
- Control Reset1
- Cooktop Controls Diagnostic ModePress any 3 different keypads in sequence
- Cooktop Controls Diagnostics ModePress any 3 different keypads in sequence
- Diagnostics ModePress CANCEL > CANCEL > START
- Display Test1
- Fault Code Viewing/Clearing1
- Oven Diagnostics ModePress CANCEL>CANCEL>START or OFF>OFF>ON within 5 seconds. Use TEMP/TIME +/- or More/Less keypads or…
- Oven Test Mode (Manual Relay Activation)Enter Diagnostics Mode (CANCEL>CANCEL>START or OFF>OFF>ON within 5 seconds). Navigate with…
- Semi Automatic Test1
- Semi Automatic Test ModeEnter Diagnostics Mode (CANCEL>CANCEL>START or OFF>OFF>ON within 5 seconds). Navigate with…
- Temperature CalibrationPress Settings or Options keypad until 'Temp Calib' is displayed
- Test Mode (Manual Relay Activation)Enter Diagnostics Mode (CANCEL>CANCEL>START or OFF>OFF>ON within 5 seconds). Navigate using…
- Test Mode (Manual Relay Testing)1
- Usage Mode1
- Version Mode1
Full entry steps, exit procedures, and test sequences are available in Max.