Model reference
Maytag MGR4452ADB
Range
4 documents15 error codes15 service modes
Available documentation
Tech Sheet
- Gas Freestanding Range — Technical Information6 pg
Service Manual
- maytag-freestandin63 pg
- Maytag Freestanding Gas Range Repair Service Manual63 pg
Bulletin
- Service Pointer - 8178740 (Oven Starts Before Desired Temperature is Selected)2 pg
MyPros+ Max
Diagnose your Maytag MGR4452ADB.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (15)
CodeMeaning
1c1cShorted key1c2cKeyboard tail disconnected from the control board.1c31Cancel key circuit problem1c4cMicro communication failure1c5cVcc or ground fault1c6cEEPROM error detected after 5 tries during active cook.1c7cControl not calibrated1c8cCooking program error detected after 5 tries during active cook.1d11Runaway oven temperature1d21Runaway oven temperature (950°F) with door locked.3d11Temperature sensor open3d21Temperature sensor shorted4d11Door switch not closed when door is locked.4d51Door switch not open or closed9d11Door latch will not lockService modes (15)
- 24 Hour Clock Toggle["Press and hold Cancel and Delay pads for 3 to 5 seconds.","Press More + or Less
- Child Lock Out["Press and hold Cancel and Cook & Hold pads for 3 to 5 seconds until beep sounds."]
- Clock Display Toggle (On/Off)["Press and hold Cancel and Clock pads for 3 to 5 seconds."]
- Diagnostic Code DisplayPress and hold the More + pad for 3 to 5 seconds within 60 seconds of powering up the control.
- Diagnostic Code Display Mode["Must be started within 60 seconds of powering up the control.","Press and hold More + pad within…
- Factory Default Reset["Press and hold Cancel and Keep Warm pads for 3 to 5 seconds until beep sounds."]
- Keypad LockoutPress and hold Cancel and Timer pads for 3 to 5 seconds. Press More + or Less
- One-Watt Standby ModePress and hold Cancel and Less
- Oven Temperature Adjustment1. Press Bake pad. 2. Enter 550 on the digit-pad. 3. Immediately press and hold Bake pad for 3 to 5…
- Quick Test Mode["Must be entered within first 5 minutes after power up.","Press and hold Cancel and Broil pads…
- Quick Test Mode (Non-Self Clean Control)1. Within 5 minutes of power-up, press and hold Cancel and Broil pads simultaneously for 3 to 5…
- Sabbath Mode1
- Temperature Display (°F/°C)Press and hold Cancel and Bake pads for 3 to 5 seconds. Press More + or Less
- Temperature Display Toggle (°F/°C)["Press and hold Cancel and Bake pads for 3 to 5 seconds.","Press More + or Less
- Twelve Hour Shutoff
Full entry steps, exit procedures, and test sequences are available in Max.