Maytag Range Error Code 1c7c
Control not calibrated; calibration value out of range
Control not calibrated; calibration value out of range. Displays 'CAL' in time digits and completely disables oven.
First step from the service manual
Replace control (requires Power On Reset to clear).
The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.
Get the full diagnostic procedure for 1c7c.
- Step-by-step tests with expected resistance, voltage, and continuity values
- Wiring diagram references and connector pinouts from the OEM service manual
- Verified part numbers when replacement is required
$29/month · Cancel anytime · Or $9.95 3-day pass
What 1c7c means on a Maytag range
Error code 1c7c on a Maytag range indicates the control board has detected that its internal calibration value is outside the acceptable range. This means the stored calibration data the board uses to regulate cooking temperatures, timing, or sensor interpretation has been corrupted, lost, or was never properly set. The board cannot operate reliably in this state, and the manufacturer's fix is control board replacement rather than recalibration through software.
For a homeowner, think of the control board as the brain of your range. It stores specific values that tell it how to translate your settings into precise heat levels. When error 1c7c appears, the board is flagging that its internal reference numbers have drifted or been lost entirely, meaning it cannot accurately control the oven or cooktop functions. This is not a sensor failure or a wiring problem elsewhere in the unit.
Because the calibration value is stored directly on the control board, replacing the board is the only reliable fix. There is no field recalibration procedure available to reset this value on most Maytag models affected by this code. Attempting to continue using the range may result in inaccurate temperatures or unpredictable behavior.
Source: manufacturer service documentation.
Common causes of 1c7c
- 01
Failed or corrupted control board memory
Part replacementThe control board's non-volatile memory, where calibration values are stored, can fail due to age, power surges, or component degradation. When this happens, the stored calibration data becomes corrupted or lost, triggering the 1c7c code.
- 02
Power surge or voltage spike to the control board
Part replacementA sudden voltage spike from the power supply or a lightning event can corrupt the calibration data stored on the board's memory chip. The board may otherwise appear functional but will display 1c7c because the calibration registers are no longer valid.
- 03
Incomplete or failed factory calibration on a replacement board
Part replacementIf a control board was previously replaced with an uncalibrated or improperly flashed unit, the calibration value may have been out of range from the start. This can cause 1c7c to appear immediately after installation of a new board.
Frequently asked questions about 1c7c
What does error code 1c7c mean on a Maytag range?
How do I fix error code 1c7c on a Maytag range?
Is it safe to use my Maytag range when error code 1c7c is showing?
How much does it cost to fix a 1c7c error on a Maytag range?
Will resetting my Maytag range clear the 1c7c error code?
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass