Model reference
Maytag YMER8772WS1
Range
5 documents27 error codes8 service modes
Available documentation
Tech Sheet
- Tech Sheet - W10239468 - Rev A8 pg
- Fiche technique - Tech Sheet W102394698 pg
Service Manual
- Troubleshooting Gas and Electric Freestanding Range Electronic Controls70 pg
Service Flash
- Service Pointer - 4317472 (Oven Rack Falling)2 pg
Installation Guide
- Installation Instructions12 pg
MyPros+ Max
Diagnose your Maytag YMER8772WS1.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (27)
CodeMeaning
F1Control failure or UL A/D error(s) detected in the control board.F1 E*Control board failure (all F1 sub-codes indicate control fault).F1-E0Internal board failure.F1-E5Internal board failure.F1-E7Internal board failure.F1-E9Internal board failure.F2Shorted/stuck key detected on the control keypad.F2-E0Keypad disconnected.F2-E1Stuck key.F2-E2Cancel key error.F3Oven sensor opened or oven sensor shorted.F3 E0Oven temperature sensor fault (open or shorted)F3 E1Lower oven temperature sensor fault (MRC II double oven models).F3 E2Warming drawer temperature sensor fault.F3-E0Main oven temperature sensor open or shorted.F3-E2Warming drawer (WD) sensor open or shorted.F5 E0Door position switch faultF5 E1Door latch switch/system faultF5 E2Door switch fault.F5-E0Door and switches do not agree during Clean mode.F5-E1Door latch not operating during Clean mode.F6 E*Control communication failure.F6-E0Lost wide (wired) communication.F6-E1Over temperature during cook mode.F6-E2Over temperature during clean mode.F6-E3Over temperature in warming drawer.F9House miswiredService modes (8)
- Diagnostics ModeWith the oven not in cooking, broiling, or cleaning mode, press CANCEL > CANCEL > START within a 5…
- LCC Diagnostic Mode (LCC90/LCC95/LCC180)["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME '+' key to cycle through diagnostic…
- LCC190 Diagnostic Mode (Self Clean, Convection models)["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME or TEMP/HOUR '+' key to cycle through…
- MRC Diagnostic Mode["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME '+' key to cycle through diagnostic…
- MRC Diagnostic Mode (Fan/True Convection Electric - Oven Light entry)["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME '+' key to cycle through diagnostic…
- MRC II Diagnostic Mode (Number 3 key entry - KitchenAid models)["Press OFF/OFF/START or CANCEL/CANCEL/START in sequence.","Press the number '3' key to cycle…
- MRC II Diagnostic Mode (TEMP/TIME entry)["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME '+' keypad to cycle through diagnostic…
- Temperature AdjustmentPress and hold OVEN LIGHT key for 5 seconds
Full entry steps, exit procedures, and test sequences are available in Max.
Related Maytag range models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass