mypros+
Model reference

Sub-Zero ID-30RP

Refrigerator

2 documents72 error codes1 service mode

Available documentation

Service Manual

  • Sub-Zero Service Manual: Integrated Drawer — Service Manual199 pg
    Covers this model

Parts Manual

  • Sub-Zero Parts Manual: Integrated Drawers — Parts Manual57 pg
    Covers this model
MyPros+ Max

Diagnose your Sub-Zero ID-30RP.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (72)

View all 72 error codes
15 C 00AC condenser fan relay stuck open15 C 01AC condenser fan relay stuck closed15 U 00Water valve no current detected during activated call for water or dispense.15 U 01Water valve current still detected after valid dispense or ice maker fill20 2 00Defrost bi-metal stuck open.20 2 01Defrost bi-metal stuck closed.20 2 05Defrost bi-metal mis-wire with normal temps20 2 06Defrost bi-metal mis-wire with overheat20 2 50Defrost heater open circuit.30 8 05Icemaker no water valve input signal35 1 00Zone 1 evaporator fan open circuit.35 1 33Zone 1 fan speed set too low35 1 34Zone 1 fan speed set too high35 2 00Zone 2 evaporator fan open circuit.35 2 33Zone 2 fan speed set too low35 2 34Zone 2 fan speed set too high35 3 00Zone 3 evaporator fan open circuit.35 3 33Zone 3 fan speed set too low35 3 34Zone 3 fan speed set too high35 A 00Air filter fan open circuit.35 C 00DC condenser fan open circuit.35 C 33DC condenser fan speed set too low35 C 34DC condenser fan speed set too high40 1 00Zone 1 stepper current fault40 1 40Zone 1 excessive compressor runtime.40 1 87Zone 1 stepper cooling fault40 2 00Zone 2 stepper current fault40 2 40Zone 2 excessive compressor runtime.40 2 87Zone 2 stepper cooling fault40 3 40Zone 3 excessive compressor runtime.40 9 40Dispenser active for maximum fill time40 b 00Baffle stepper current fault.40 b 87Baffle cooling/position fault.45 1 00Lights open circuit45 1 01Lights short circuit45 2 00Lights open circuit45 2 01Lights short circuit90 5 80No UIM (User Interface Module) communications.90 H 80High voltage micro (CCM) no communication90 H 82High voltage micro (CCM) partial communications90 H 83High voltage micro (CCM) bad communications90 H 84High voltage micro (CCM) initialization fault.

Service modes (1)

  • Service Options1

Full entry steps, exit procedures, and test sequences are available in Max.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass