Model reference
Thermador PO30201
Oven
2 documents32 error codes2 service modes
Available documentation
Service Manual
- SERVICE MANUAL for Thermador Professional Series Built-in Wall Ovens21 pg
- Service Manual for Thermador Professional Series Built-in Wall Ovens21 pg
MyPros+ Max
Diagnose your Thermador PO30201.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (32)
CodeMeaning
E000Control module and user interface are mismatched (wrong module combination).E003User interface electronics exceed 185°F/85°C (electronics too hot).E005Loss of communication between user interface and control module.E009ROM check error in user interface (start-up error).E010Data memory error in user interface.E011Continuous pushing of a single key detected for 10 seconds.E012Defective user interface PCB temperature sensor.E014ON/OFF key does not work.E032Continuous pushing of multiple keys detected for 10 seconds.E101Cavity 1 temperature sensor open circuit.E104Cavity 1 temperature sensor shorted.E106Cavity 1 door latch does not lock.E107Cavity 1 door latch does not unlock.E115Cavity 1 temperature in unlocked cavity too high.E116Cavity 1 meat probe error.E118Cavity 1 cooling fan supervision error (fan speed too low or too high).E122Cavity 1 probe sensor temperature too high.E123Cavity 1 probe sensor temperature too low.E124Cavity 1 door switch in undefined state.E126Cavity 1 door latch in undefined state.E201Cavity 2 temperature sensor open circuit.E204Cavity 2 temperature sensor shorted.E206Cavity 2 door latch does not lock.E207Cavity 2 door latch does not unlock.E215Cavity 2 temperature in unlocked cavity too high.E218Cavity 2 cooling fan supervision error (fan speed too low or too high).E224Cavity 2 door switch in undefined state.E226Cavity 2 door latch in undefined state.E303Control module electronics exceed 212°F/100°C (electronics too hot).E309ROM check error in control module.View all 32 error codes
Service modes (2)
- Demo Mode["Tie the black and red wires together.","The display and lights will work on 120VAC."]
- Service Mode["Set oven mode knob(s) to OFF.","Set upper oven temperature knob to 100°.","Press SELECT, up…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Thermador oven models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass