Model reference

Whirlpool 110C86742700

Dryer

2 documents25 error codes3 service modes

Available documentation

Tech Sheet

  • Kenmore Whirlpool Dryer 110 C86742700 Tech Sheet W10143268A16 pg
    Covers this model

Tech Tip

  • Instruction Sheet - W10128087- Rev A - Special Handling7 pg
    Covers this model
MyPros+ Max

Diagnose your Whirlpool 110C86742700.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax

Error codes (25)

CodeMeaning
AFLow inlet air flow detected at installation.F:01Primary control failure.F:02Stuck button or user interface mismatch (appears ONLY in Diagnostic Test Mode).F:20No voltage detected at the heater relay (appears ONLY in Diagnostic Test Mode).F:22Outlet thermistor is open.F:23Outlet thermistor has shorted.F:24Inlet thermistor is open (appears ONLY in Diagnostic Test Mode).F:25Inlet thermistor is shorted (appears ONLY in Diagnostic Test Mode).F:26Motor drive system failure.F:28Moisture sensor strip is open (appears ONLY in Diagnostic Test Mode).F:29Moisture sensor strip has shorted (appears ONLY in Diagnostic Test Mode).F:30Restricted airflow condition exists (appears ONLY in Diagnostic Test Mode).F:31Low voltage condition (less than 30 V) detected (appears ONLY in Diagnostic…F:50No voltage detected at the water valve relay (appears ONLY in Diagnostic Test…F:70No communication between the machine control and the console electronics.F:71No communication between the machine control and the console electronics.F:72Console electronics failure (F:72 through F:78).F:73Console electronics failure (F:72 through F:78).F:74Console electronics failure (F:72 through F:78).F:75Console electronics failure (F:72 through F:78).F:76Console electronics failure (F:72 through F:78).F:77Console electronics failure (F:72 through F:78).F:78Console electronics failure (F:72 through F:78).L2Low line voltage (less than 30 V) detected at installation.PFPower failure occurred while the dryer was running.

Service modes (3)

  • Customer-Focused Drying Mode Adjustment (CF1/CF2/CF3)1
  • Manual Load Test Mode1. Ensure dryer is in standby mode (plugged in with all indicators off, or with only the Clothes…
  • Service Diagnostic Test Mode1

Full entry steps, exit procedures, and test sequences are available in Max.

75,000+ service documents · 20,000+ error codes · 100+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax