mypros+
Model reference

Whirlpool WED9600TB0

Dryer

10 documents25 error codes7 service modes

Available documentation

Tech Sheet

  • Tech Sheet - WED9600TW112 pg
    Covers this model
  • TECH SHEET - W10143265 - Rev A12 pg
    Covers this model

Service Flash

  • Dry Time Display Appears to Jump or Stall4 pg
    Covers this model
  • Service Pointer - 8178790 (Door not Closing)6 pg
    Covers this model

Tech Tip

  • Instruction Sheet - W10110658 - Rev A - Special Handling1 pg
    Covers this model
  • Instruction Sheet - W10128087- Rev A - Special Handling7 pg
    Covers this model
  • Instruction Sheet2 pg
    Covers this model
  • Instruction Sheet12 pg
    Covers this model

Other

  • Service Pointer 81787334 pg
    Covers this model

Quick Reference

  • Quick Reference Manual2 pg
    Covers this model
MyPros+ Max

Diagnose your Whirlpool WED9600TB0.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (25)

CodeMeaning
AFLow inlet air flow condition detected at install.F:01Primary control failure.F:02Stuck button or user interface mismatch (appears ONLY in Diagnostic Test Mode).F:20No voltage detected at the heater relay (appears ONLY in Diagnostic Test Mode).F:22Outlet thermistor is open.F:23Outlet thermistor has shorted.F:24Inlet thermistor is open (appears ONLY in Diagnostic Test Mode).F:25Inlet thermistor is shorted (appears ONLY in Diagnostic Test Mode).F:26Motor drive system failure.F:28Moisture sensor strip is open (appears ONLY in Diagnostic Test Mode).F:29Moisture sensor strip has shorted (appears ONLY in Diagnostic Test Mode).F:30Restricted air flow condition exists (appears ONLY in Diagnostic Test Mode).F:31Low voltage condition (less than 30V) detected (appears ONLY in Diagnostic Test…F:50No voltage detected at the water valve relay (appears ONLY in Diagnostic Test…F:70No communication between the machine control and the console electronics.F:71No communication between the machine control and the console electronics.F:72Console electronics failure (F:72 through F:78).F:73Console electronics failure (F:72 through F:78).F:74Console electronics failure (F:72 through F:78).F:75Console electronics failure (F:72 through F:78).F:76Console electronics failure (F:72 through F:78).F:77Console electronics failure (F:72 through F:78).F:78Console electronics failure (F:72 through F:78).L2Low line voltage (less than 30V) detected at installation.PFPower failure occurred while the dryer was running.

Service modes (7)

  • Customer-Focused Drying Mode Adjustment["In Standby mode (dryer plugged in but not powered up), press and hold the Dryness Level button…
  • Customer-Focused Drying Mode Adjustment (CF1/CF2/CF3)["In Standby mode (dryer plugged in but not powered up), press and hold the Dryness Level button…
  • Diagnostic Test Mode["Ensure dryer is in standby mode (plugged in with all indicators off, or with only the Done…
  • Inlet Air Flow Diagnostic["Enter the Diagnostic Test Mode and wait for the 5 second delay and cycle through any saved fault…
  • Line Voltage Diagnostic["Enter the Diagnostic Test Mode and wait for the 5 second delay and cycle through any saved fault…
  • Manual Load Test["Ensure dryer is in standby mode (plugged in with all indicators off, or with only the Done…
  • Service Diagnostic Test Mode["Ensure dryer is in standby mode (plugged in with all indicators off, or with only the Done…

Full entry steps, exit procedures, and test sequences are available in Max.