mypros+
Model reference

Whirlpool WEL98HEBU0

Dryer

4 documents29 error codes5 service modes

Available documentation

Tech Sheet

  • Tech Sheet - W10436726 - Rev A60 pg
    Covers this model

Quick Reference

  • Quick Reference Manual2 pg
    Covers this model
  • Quick Reference Manual1 pg
    Covers this model

Installation Guide

  • Instrucciones de instalacion23 pg
    Covers this model
MyPros+ Max

Diagnose your Whirlpool WEL98HEBU0.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (29)

CodeMeaning
12-1No communication between ECM and Appliance Control Unit (ACU)12-2No link between ECM and Wireless Router12-3No link between ECM and Internet12-4Antenna A problem12-5Antenna B problem12-6Current Transformer A problem12-7Provisioning problemF1E1Indicates a Cycle Control Unit (CCU) problem.F2E1Indicates a stuck button (depressed for over 20 seconds) or UI mismatch…F3E1Exhaust thermistor is open; temperature drops below 18°F (> 50k ohms).F3E2Exhaust thermistor has shorted; temperature above 250°F (< 500 ohms).F3E3Inlet thermistor is open; temperature drops below 18°F (> 245k ohms).F3E4Inlet thermistor is shorted; temperature above 781°F (< 19.6 ohms).F3E5Inlet and exhaust thermistors are both open; will occur if P14 connector is not…F3E6Moisture sensor strip is open; appears only in service diagnostic mode.F3E7Moisture sensor strip has shorted; appears only in service diagnostic mode.F4E1No voltage detected at the heater relay; appears only in service diagnostic…F4E3Low air flow detected that may affect dryer performance.F4E4Low L2 voltage (less than 50V) detected at the CCU.F6E1Communication error from UI to CCU has not been detected.F6E2Communication error from CCU to UI has not been detected.FCE0Communication error between ECM and CCU (model WEL98 only).FCE1Communication error from dryer to wireless router (model WEL98 only).FCE2Wireless router cannot communicate with the internet (model WEL98 only).FCE3Antenna A (J2) is bad (model WEL98 only).FCE4Antenna B (J11) is bad (model WEL98 only).FCE5Current Transformer A not functioning at J12 (model WEL98 only).FCE6Current Transformer B not functioning at J12 (model WEL98 only).FCE7Provisioning failure

Service modes (5)

  • Component Activation - Dryer["Activate Service Diagnostic Mode","From the Diagnostic Home Screen, select Component…
  • Component Activation - Washer["Activate Service Diagnostic Mode","From the Diagnostic Home Screen, select Component…
  • Quick Diagnostic Test["Enter Service Diagnostics mode.","Navigate to Error Diagnostic menu.","Select 'Quick Diagnostic…
  • Service Diagnostics["Ensure dryer is in standby mode (plugged in with all indicators off).","Select any three buttons…
  • UI Component Test["Enter Service Diagnostics mode.","Navigate to Component Activation menu.","Select 'UI Component…

Full entry steps, exit procedures, and test sequences are available in Max.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass