Model reference
Whirlpool YMEDB850WB1
Dryer
5 documents25 error codes4 service modes
Available documentation
Tech Sheet
- Tech Sheet - W10156735A16 pg
Service Flash
- Motor Pulley Comes Loose2 pg
- Special Handling for W102017853 pg
Tech Tip
- Instruction Sheet2 pg
Installation Guide
- Instrucciones de instalacion17 pg
MyPros+ Max
Diagnose your Whirlpool YMEDB850WB1.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (25)
CodeMeaning
AFRestricted air flow condition exists.F:01Primary control failure.F:02Stuck button or user interface mismatch (only appears in diagnostic test mode).F:20No voltage detected at the heater relay (only appears in diagnostic test mode).F:22Exhaust thermistor is open.F:23Exhaust thermistor has shorted.F:24Inlet thermistor is open (only appears in diagnostic test mode).F:25Inlet thermistor is shorted (only appears in diagnostic test mode).F:26Motor drive system failure.F:28Moisture sensor strip is open (only appears in diagnostic test mode).F:29Moisture sensor strip has shorted (only appears in diagnostic test mode).F:30Restricted air flow condition exists (only appears in diagnostic test mode).F:31Low voltage condition (less than 30V) detected on L2 (only appears in…F:50No voltage detected at the water valve relay (only appears in diagnostic test…F:70No communication between the machine control and the console electronics.F:71No communication between the machine control and the console electronics.F:72Console electronics failure (F:72 through F:78).F:73Console electronics failure (F:72 through F:78).F:74Console electronics failure (F:72 through F:78).F:75Console electronics failure (F:72 through F:78).F:76Console electronics failure (F:72 through F:78).F:77Console electronics failure (F:72 through F:78).F:78Console electronics failure (F:72 through F:78).L2Low or no line voltage detected (less than 50V) at installation.PFPower failure occurred while the dryer was running.Service modes (4)
- Customer-Focused Drying Mode Adjustment1
- Diagnostic Test Mode1
- Factory Default Reset1
- Manual Load Test1. Dryer must be in standby mode (plugged in with all indicators off, or with only the Dry…
Full entry steps, exit procedures, and test sequences are available in Max.