Model reference

Wolf CTE-2

Cooktop

2 documents45 error codes3 service modes

Available documentation

Service Manual

  • CT Electric Cook Top Service Manual44 pg
    Covers this model
  • Service Manual Electric Cooktop-2 (CTE-2) Series5 pg
    Covers this model
MyPros+ Max

Diagnose your Wolf CTE-2.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax

Error codes (45)

CodeMeaning
E01Power module ambient temperature has reached or exceeded its temperature limit.E02Power module heat sink temperature has reached or exceeded its temperature…E05Power module ambient temperature sensor has a value indicating a disconnected…E06Power module ambient sensor is shorted to heatsink sensor.E07The power module informs display board which model it is; if the value is…E08Display Board is unable to communicate to Keyboard (Keyboard Communications…E09Keyboard internally detects communications errors and reports back to display…E10Display Board is unable to communicate to power module (Display Board Detected…E11Power module is unable to communicate to display board (Power module detected…E13Keyboard internally tests for key opens, shorts, and signal quality issues and…E14Keyboard detects internal EEPROM failure and reports to the Display Board.E15Keyboard internally recalibrates periodically and reports failures to the…E16Keyboard internally detects communications errors and reports this back to the…E17Failure of the Keep Alive capacitor to discharge after a Keep Alive recoveryE18Power board EEPROM CRC FailureE19A shorted relay or triac was detected on the Power module (Run Time Diagnostics…E20Power module relay power circuit fault was detected (Element Supervisor Fail).E30Display Board detected that the Least Significant Digit of a display bar graph…E50Power module heatsink thermistor has a value indicating a disconnected sensor…E56Power module Microcontroller Flash memory CRC failure.E57Display Board Microcontroller Flash memory CRC failure.E58Power module Microcontroller Configuration Fuse failure.E59Display Board Microcontroller Configuration Fuse failure.E60Invalid internal state; Display Board Zero-Cross signal failure (Power module…E63Invalid internal state; Display Board Zero-Cross signal failure (Zero Cross…E64Self Test ResultE65Self Test ResultE66Self Test ResultE67Self Test ResultE69Microcontroller internal RAM/Register error (Power RAM Error).
View all 45 error codes

Service modes (3)

  • Diagnostic Mode["Ensure the cooktop is in LOCK mode.","Press and hold the [OFF] key for 5 seconds.","A beep will…
  • Lock Mode["Press and hold the LOCK KEY for 3 seconds.","The unit will beep 3 times and the light within the…
  • Showroom Mode["Ensure the cooktop is in LOCK mode.","Press and hold the front element MELT key for 5…

Full entry steps, exit procedures, and test sequences are available in Max.

75,000+ service documents · 20,000+ error codes · 100+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax