mypros+
Model reference

Wolf ICBCT15I/S

Cooktop

3 documents35 error codes3 service modes

Available documentation

Service Manual

  • Wolf Service Manual: ICB CT Induction Cooktop — Service Manual39 pg
    Covers this model

Parts Manual

  • Wolf Revision 1: Prior to Serial 17600000 — Parts Manual6 pg
    Covers this model
  • Wolf Revision 2: After Serial 17600000 — Parts Manual6 pg
    Covers this model
MyPros+ Max

Diagnose your Wolf ICBCT15I/S.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (35)

CodeMeaning
E1Ambient temperature too high; unit enters Lock Mode until ambient temperature…E10Generator 3 communication error; burners associated with generator 3 disabled.E11A/D failure; cooktop enters Lock Mode and displays error code in timer display.E12Universal OFF button failure; watchdog timer not reset on key release within…E13Shorted key failure; watchdog timer not reset on key release, affected burner…E19Read line failure; control enters Lock Mode and displays error until corrected.E2Generator 1 heatsink temperature too high; burners unavailable until heatsink…E20Generator 1 burner (F,FR,FC) sensor shorted; affected burner shuts down when…E21Generator 2 burner (FL) sensor shorted; affected burner shuts down when A/D…E22Generator 1 burner (F,FR,FC) sensor open; affected burner shuts down when A/D…E23Generator 2 burner (FL) sensor open; affected burner shuts down when A/D value…E3Generator 2 heatsink temperature too high; burners unavailable until heatsink…E30Generator 1 burner (F,FR,FC) ON LED failure; affected burner not available.E31Generator 1 burner (R,RR,RC) ON LED failure; affected burner not available.E32Generator 2 burner (RL) ON LED failure; affected burner not available.E33Generator 2 burner (FL) ON LED failure; affected burner not available.E34Generator 3 burner (RR) ON LED failure; affected burner not available.E4Generator 3 heatsink temperature too high; burners unavailable until heatsink…E40Generator 1 burner (R,RR,RC) sensor shorted; affected burner shuts down.E41Generator 2 burner (RL) sensor shorted; affected burner shuts down.E42Generator 3 burner (RR) sensor shorted; affected burner shuts down.E43Generator 1 burner (R,RR,RC) sensor open; affected burner shuts down.E44Generator 2 burner (RL) sensor open; affected burner shuts down.E45Generator 3 burner (RR) sensor open; affected burner shuts down.E5Open ambient thermistor detected (recorded after 5 minutes of consecutive open…E50Generator 1 open heat sink thermistor; affected burner shuts down.E51Generator 2 open heat sink thermistor; affected burner shuts down.E52Generator 3 open heat sink thermistor; affected burner shuts down.E53Generator 1 shorted heat sink thermistor; affected burner shuts down.E54Generator 2 shorted heat sink thermistor; affected burner shuts down.
View all 35 error codes

Service modes (3)

  • Annunciator Setup (User Options)1
  • Diagnostic Mode1
  • Showroom Mode1

Full entry steps, exit procedures, and test sequences are available in Max.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass