What the F3 error code actually means

Your Asko dryer has stopped because the temperature sensor, called a thermistor, is either broken or not sending a signal the dryer can read. The dryer shuts itself down to prevent any risk of overheating until the sensor problem is resolved. A technician will need to test the sensor and its wiring to find out whether the part itself has failed or if a loose connection is the cause.

Diagnostic procedure

The full F3 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check thermistor resistance; a healthy thermistor reads between 60 kohm and 40 kohm at 20-30°C. Check for broken connections or thermal contact with fan casing.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock F3 procedure $9.95

Or subscribe: $29/month for all codes plus Max AI diagnostics, with 70 Max messages a day.

Most common causes of F3

Ranked by how often they cause this code
  1. 1Failed thermistor
  2. 2Broken or disconnected wiring
  3. 3Poor thermal contact with the fan casing
  4. 4Shorted wiring harness
  5. 5Faulty control board

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about F3

What does F3 mean on a Asko dryer?
F3 on an Asko dryer signals a thermistor fault, meaning the control board detected an open circuit or short circuit in the temperature sensor. The thermistor is mounted on the fan casing and is responsible for monitoring air temperature during the drying cycle. When the resistance reading falls outside the expected range of 40 to 60 kohm at room temperature, the dryer interrupts the program and displays F3 to prevent uncontrolled heating.
Is it safe to keep using the dryer when F3 is displayed?
No, you should not continue operating the dryer while F3 is active. The thermistor is the primary temperature monitoring component, and without accurate sensor data the dryer cannot regulate heat safely. The program is interrupted automatically for this reason, and running the dryer with a bypassed or faulty sensor creates a risk of overheating.
Will resetting the dryer clear the F3 error?
A power reset may clear the error display temporarily, but F3 will return as soon as the dryer attempts to run and the control board reads the faulty thermistor signal again. The underlying fault in the thermistor or its wiring must be identified and corrected before the error will stay cleared. Repeatedly resetting without addressing the root cause will not resolve the problem.
Can I fix the F3 error myself?
A knowledgeable DIYer can diagnose F3 using a multimeter to check thermistor resistance and inspect the wiring harness for broken or loose connections. If the thermistor itself has failed, replacing it is a straightforward repair involving disconnecting the sensor from the fan casing and fitting a new one. However, if the wiring harness or control board is involved, the repair becomes more complex and professional service is recommended.
How much does it cost to repair an F3 error on an Asko dryer?
Repair costs vary depending on the root cause. A thermistor part is generally in the range of $15 to $50, making it one of the more affordable fixes if wiring is intact. If a service technician is needed for diagnosis and installation, total costs including labor typically range from $100 to $250. Control board replacement, if required, can bring costs considerably higher.