Carrier Furnace Error Code 31
Pressure switch did not close or reopened; if open longer than 5 minutes, inducer shuts off for 15 minutes before retry.
SourceCarrier 58DLA/DLX Furnace - Service Manual: Installation & MaintenanceFig. 55 / Service Label
Diagnostic procedure
The full 31 procedure
Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.
MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check for proper vent sizing, low inducer voltage (115VAC), defective inducer motor, defective pressure switch, inadequate combustion air supply, disconnected or obstructed pressure tubing, low inlet gas pressure (if LGPS used), restricted vent, or excessive wind.
SourceCarrier 58DLA/DLX Furnace - Service Manual: Installation & MaintenanceFig. 55 / Service Label