Carrier Furnace Error Code 32
Low-heat pressure, draft safeguard (when used), or auxiliary limit switch (downflow only) did not close or…
Low-heat pressure, draft safeguard (when used), or auxiliary limit switch (downflow only) did not close or reopened; if open longer than 5 minutes, inducer shuts off for 15 minutes before retry.
First step from the service manual
Check for defective blower motor or capacitor, restricted vent, proper vent sizing, low inducer voltage (115VAC), disconnected or obstructed pressure tubing, excessive wind, defective inducer motor, defective pressure switch, or inadequate combustion air supply.
The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.