Carrier Furnace Error Code 34

Ignition proving failure; if flame is not sensed during the trial for ignition period, the control will repeat the ignition sequence 3 more times before lockout #14 occurs.

SourceCarrier 58DLA/DLX Furnace - Service Manual: Installation & MaintenanceFig. 55 / Service Label

Diagnostic procedure

The full 34 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check that flame sensor is not grounded, clean oxide buildup on flame sensor with fine steel wool, verify proper flame sense microamps (0.5 microamps DC min, 4.0-6.0 nominal), check gas valve, manual valve shut-off, defective hot surface igniter, control ground continuity, low inlet gas pressure, inadequate flame carryover, and green/yellow wire connection to furnace sheet metal.

SourceCarrier 58DLA/DLX Furnace - Service Manual: Installation & MaintenanceFig. 55 / Service Label

More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock 34 procedure $9.95

Or subscribe: $29/month for all codes plus Max diagnostics, with 70 Max messages a day. Plus applicable tax.