Carrier Furnace Error Code 43

Low-heat pressure, draft safeguard (when used), or auxiliary limit switch (when used) open while high-heat pressure switch is closed.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the 43 error code actually means

Your Carrier furnace detected a disagreement between two internal safety sensors that monitor airflow during heating. One sensor is reading as if there is no airflow while another says airflow is fine, which is a contradiction the furnace cannot safely ignore. The furnace shuts down to prevent potentially dangerous operation until the problem is diagnosed and corrected.

Diagnostic procedure

The full 43 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check for pressure switch stuck open, disconnected or obstructed pressure tubing; refer to codes 32 and 33.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock 43 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of 43

Ranked by how often they cause this code
  1. 1Low-heat pressure switch stuck open
  2. 2Disconnected or cracked pressure tubing
  3. 3Blocked or obstructed pressure port
  4. 4Auxiliary limit switch or draft safeguard switch open
  5. 5Failed high-heat pressure switch reading incorrectly as closed

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about 43

What does 43 mean on a Carrier furnace?
Code 43 on a Carrier furnace means the low-heat pressure switch, draft safeguard switch, or auxiliary limit switch is reading open at the same time the high-heat pressure switch is reading closed. This contradiction in pressure switch states indicates a problem with draft sensing, pressure tubing, or one of the switches themselves. The furnace shuts down as a safety precaution until the conflict is resolved.
Is a Carrier furnace code 43 a safety issue?
Yes, code 43 is a safety-related lockout. The pressure switches that trigger this code are designed to confirm that proper combustion air and exhaust draft are present before and during burner operation. When the control board detects a conflict between these switch states, it stops the furnace to prevent incomplete combustion or unsafe flue gas conditions. Do not attempt to bypass the pressure switches.
How much does it cost to repair a Carrier furnace showing code 43?
Repair costs depend on the root cause. Reconnecting or replacing pressure tubing is generally inexpensive, with parts typically costing a few dollars to around $15 to $30. A replacement pressure switch generally ranges from $20 to $75 or more depending on the specific switch. Adding in labor, a service call to diagnose and repair a code 43 fault typically falls in the range of $100 to $350, depending on the technician's rates and the time required for diagnosis.
Can I fix a Carrier furnace code 43 myself?
Some causes of code 43 are DIY-accessible, such as reconnecting a loose pressure tube or clearing a blocked pressure port. However, testing pressure switches accurately requires a manometer, and diagnosing an auxiliary limit or draft safeguard switch often requires understanding of the furnace wiring schematic. If basic tubing inspections do not resolve the fault, a qualified HVAC technician should complete the diagnosis.
Will resetting my Carrier furnace clear error code 43?
Resetting the furnace by cycling the power may temporarily clear the lockout and allow the furnace to attempt another ignition sequence, but the code will return if the underlying problem is not corrected. A reset is useful as a first step to see if the fault was a one-time anomaly, but recurring code 43 faults require proper diagnosis of the pressure switch circuit, tubing, and any installed auxiliary switches.