Cove Dishwasher Error Code 900112
MCM
MCM: UIM slave firmware not compatible.
First step from the service manual
Replace the UIM.
The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.
Get the full diagnostic procedure for 900112.
- Step-by-step tests with expected resistance, voltage, and continuity values
- Wiring diagram references and connector pinouts from the OEM service manual
- Verified part numbers when replacement is required
$29/month · Cancel anytime · Or $9.95 3-day pass
What 900112 means on a Cove dishwasher
Error code 900112 on a Cove dishwasher indicates a firmware incompatibility between the Master Control Module (MCM) and the User Interface Module (UIM). The UIM operates as a slave device on the appliance's internal communication bus, meaning it receives commands and synchronization signals from the MCM. When the MCM detects that the UIM's installed firmware version does not match the expected protocol or version range, it throws this error to prevent unpredictable behavior or unsafe operation.
This type of error most commonly appears after a partial or failed firmware update, or when a replacement UIM is installed with a firmware version that does not align with the MCM currently in the machine. The two modules must run compatible firmware builds to communicate correctly over the control bus. If the handshake or version check fails during initialization, the dishwasher will halt and display code 900112 rather than proceed with a potentially miscommunicated cycle.
The primary corrective action is replacement of the UIM, which typically resolves the incompatibility by installing a unit with current, compatible firmware. In some cases, a replacement UIM may also need a firmware update before the MCM will accept it. If a new UIM does not resolve the error, the MCM itself may be the source of an outdated or corrupted firmware version, and further diagnosis of that module would be warranted.
Source: manufacturer service documentation.
Common causes of 900112
- 01
UIM with incompatible firmware version
Part replacementThe User Interface Module installed in the dishwasher is running a firmware version the MCM does not recognize or support. This is the most direct cause of code 900112 and is confirmed by the error itself.
- 02
Failed or interrupted firmware update
Wiring / connectionIf a firmware update was interrupted by a power loss or communication fault, the UIM may be left with a corrupted or partial firmware build that the MCM rejects on startup.
- 03
Recently installed replacement UIM
Part replacementA replacement UIM sourced with an older or newer firmware version than what the existing MCM expects will trigger this incompatibility error immediately upon installation.
- 04
MCM firmware mismatch
Part replacementIf the MCM itself was updated or replaced and now expects a newer UIM firmware version than what is installed, the communication check will fail and generate this code.
- 05
Communication wiring fault between MCM and UIM
Wiring / connectionDamaged or loose wiring on the control bus between the MCM and UIM can cause garbled version handshakes, mimicking a firmware incompatibility even when both modules are otherwise correct.
Frequently asked questions about 900112
What does 900112 mean on a Cove dishwasher?
Will resetting my Cove dishwasher clear error code 900112?
How do I fix error code 900112 on a Cove dishwasher?
Is it safe to use my Cove dishwasher while error code 900112 is active?
How much does it cost to repair error code 900112 on a Cove dishwasher?
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass