Electrolux Dryer Error Code EH2
Power supply voltage out of range (too HIGH)
Power supply voltage out of range (too HIGH) — power supply problems, wrong MCF, or main board error.
First step from the service manual
Check power supply voltage; verify MCF configuration.
The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.
Get the full diagnostic procedure for EH2.
- Step-by-step tests with expected resistance, voltage, and continuity values
- Wiring diagram references and connector pinouts from the OEM service manual
- Verified part numbers when replacement is required
$29/month · Cancel anytime · Or $9.95 3-day pass
What EH2 means on a Electrolux dryer
The EH2 error code on an Electrolux dryer indicates that the power supply voltage has been detected as too high, falling outside the acceptable operating range for the appliance. The dryer's main control board continuously monitors incoming line voltage, and when that voltage exceeds the upper threshold, the board triggers this fault to protect internal components from damage. This is a voltage-sensing fault rooted in either the actual incoming power supply or in a misconfiguration of the machine control function (MCF) settings.
The most common hardware cause is a genuine overvoltage condition at the wall outlet or in the home's electrical panel. Dryers typically require a stable 240V supply in North American installations, and voltage spikes, utility fluctuations, or wiring issues can push that reading out of acceptable range. In some cases, the MCF configuration stored on the control board may be set incorrectly for the installed voltage type, causing the board to misinterpret a normal voltage reading as out-of-range.
If the incoming voltage checks out correctly and the MCF configuration is confirmed accurate, the fault may point to a failure in the main control board itself, where the voltage-sensing circuitry is producing erroneous readings. Diagnosis should begin with a calibrated multimeter measurement at the terminal block or outlet to confirm actual supply voltage before suspecting internal components.
Source: manufacturer service documentation.
Common causes of EH2
- 01
High incoming line voltage
Wiring / connectionThe actual voltage at the dryer's outlet or terminal block is elevated beyond the acceptable range. Measure the supply voltage with a multimeter at the wall outlet or terminal block to confirm whether an overvoltage condition exists.
- 02
Incorrect MCF configuration
Wiring / connectionThe machine control function settings on the control board may be programmed for the wrong voltage specification, causing a normal supply voltage to register as out of range. Verify and correct the MCF configuration according to the dryer's rated voltage requirements.
- 03
Utility or grid voltage fluctuation
Wiring / connectionTemporary voltage surges from the utility supply can trigger this fault even if the supply is normally within range. Check with the utility provider or use a voltage monitor to identify intermittent overvoltage events.
- 04
Faulty main control board
Part replacementIf supply voltage and MCF settings are both confirmed correct, the voltage-sensing circuitry on the main control board may be defective and reporting a false overvoltage reading. Replacing the main control board would be required to resolve this.
- 05
Wiring or connection issue at the terminal block
Wiring / connectionLoose, corroded, or improperly wired connections at the dryer's terminal block can cause irregular voltage readings. Inspect all connections for secure contact, corrosion, and correct wiring configuration.
Frequently asked questions about EH2
What does EH2 mean on a Electrolux dryer?
How do I fix the EH2 error on my Electrolux dryer?
Is it safe to use my Electrolux dryer when EH2 is displayed?
Will resetting my Electrolux dryer clear the EH2 error?
How much does it cost to repair an EH2 error on an Electrolux dryer?
78,000+ service manuals · 160,000+ error codes · 55+ brands