What the E2.2 error code actually means

Your furnace tried to light the burner 10 times in a row, and each time the flame went out unexpectedly, so it shut itself down for safety. This usually means there is a problem with the gas supply, a dirty or faulty flame sensor, or something blocking the burner from staying lit. The furnace will not try to heat again for about an hour, and the underlying problem needs to be fixed before it will run reliably.

Diagnostic procedure

The full E2.2 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Disconnect electrical power to furnace, connect manometer to manifold pressure connector, verify manifold pressure is ~1.7" WC (NG) or ~6.0" WC (LP).
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E2.2 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E2.2

Ranked by how often they cause this code
  1. 1Incorrect manifold gas pressure
  2. 2Degraded or contaminated flame sensor
  3. 3Dirty or restricted burner assembly
  4. 4Faulty gas valve
  5. 5Flue or venting restriction

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E2.2

What does E2.2 mean on a Ingersoll Rand furnace?
E2.2 means the furnace detected and then lost the burner flame 10 times within a single call for heat, triggering a one-hour lockout. This recycle limit exists to prevent unsafe operation when the combustion system cannot maintain a stable flame. The error points to a problem with gas pressure, the flame sensor, the burner assembly, or the gas valve, all of which need to be inspected before the furnace will run normally again.
How do I fix error code E2.2 on my Ingersoll Rand furnace?
Start by measuring the manifold gas pressure with a manometer while the burner is firing: the correct value is approximately 1.7 inches WC for natural gas or 6.0 inches WC for LP. If pressure is correct, inspect and clean the flame sensor rod, check the burner ports for debris, and verify the flue is clear of obstructions. If these steps do not resolve the issue, the gas valve may need to be tested or replaced by a qualified technician.
How much does it cost to repair an E2.2 error on an Ingersoll Rand furnace?
Repair costs vary depending on the cause. Cleaning the flame sensor or burner is typically a low-cost service call, often in the range of $80 to $200 including labor. Replacing a gas valve is more involved, with parts and labor commonly ranging from $300 to $600 or more depending on the model and local rates. Diagnosing the specific cause first is the most cost-effective approach.
Can I reset the furnace to clear error code E2.2?
The furnace will automatically attempt to restart after the one-hour lockout period expires, but resetting power does not fix the root cause. If the underlying problem is not corrected, the unit will recycle again and re-enter lockout. A technician should diagnose and repair the cause before relying on the furnace for heating.
Is error code E2.2 on a Ingersoll Rand furnace a safety concern?
Yes, repeated flame loss during a heating cycle can indicate a combustion problem that should not be ignored. The one-hour lockout is a built-in safety response to prevent the furnace from continuing to cycle unsafely. Do not attempt to bypass or repeatedly reset the unit without identifying and correcting the cause, and ensure the area is ventilated if you suspect a gas supply issue.