Ingersoll Rand Furnace Error Code E3.3

Shorted pressure switch, 2nd stage (pressure switch is closed when it should be open).

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the E3.3 error code actually means

Your furnace has detected that a safety sensor called the second-stage pressure switch is in the wrong position, reading as closed when it should be open. This prevents the furnace from running to avoid a potentially unsafe condition. The furnace needs to have this switch inspected and likely replaced before it will operate normally again.

Diagnostic procedure

The full E3.3 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Cycle power OFF then ON, verify PS2 orientation is correct, measure 24V across PS2 (brown to yellow).
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E3.3 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E3.3

Ranked by how often they cause this code
  1. 1Stuck or failed PS2 pressure switch
  2. 2Wiring short across PS2 terminals
  3. 3Incorrect PS2 orientation or installation
  4. 4Condensate or moisture in pressure switch tubing
  5. 5Faulty control board output

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E3.3

What does E3.3 mean on a Ingersoll Rand furnace?
E3.3 means the second-stage pressure switch (PS2) is detected as closed when it should be in the open position. This is a safety fault that prevents the furnace from operating. The control board monitors PS2 for correct open and closed states during the ignition sequence, and a closed switch at the wrong time triggers this lockout.
How do I fix the E3.3 error on my Ingersoll Rand furnace?
Start by cycling power off and back on, then visually inspect PS2 for correct orientation and check its wiring harness for shorts or damage. Use a multimeter to measure 24 volts AC across PS2 terminals (brown wire to yellow wire) to confirm proper voltage. If the switch remains closed at rest with no inducer running, the switch should be replaced. If wiring damage is found, repair or replace the affected section of the harness.
How much does it cost to repair an E3.3 error on an Ingersoll Rand furnace?
If the repair requires only wiring corrections or switch reorientation, costs may be limited to a service call fee, typically in the range of $75 to $150. If a new second-stage pressure switch is needed, parts generally range from $20 to $80 depending on the specific switch, with labor bringing the total repair to $100 to $250 in most cases. Control board replacement, if required, would increase costs significantly.
Will resetting the furnace clear the E3.3 error code?
Cycling the power off and then back on is the recommended first step and may temporarily clear the code if the fault was a transient glitch. However, if PS2 is physically stuck closed, shorted by wiring, or incorrectly installed, the error will return as soon as the furnace attempts to run again. A power cycle should be followed by a full inspection of PS2 and its wiring.
Is the E3.3 error on an Ingersoll Rand furnace a safety concern?
Yes, the furnace locks out with E3.3 precisely because the pressure switch is part of the combustion safety system. A pressure switch stuck closed could indicate a fault that, if bypassed, might allow the furnace to operate outside of safe pressure parameters. The furnace should not be operated with a known faulty pressure switch, and the condition should be diagnosed and corrected before restoring normal operation.