Lennox Heat Pump Error Code DS2 OFF / DS1 OFF

No power (24V) to control terminals R & C or board failure.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the DS2 OFF / DS1 OFF error code actually means

Your Lennox heat pump's control board is not getting the low-voltage electrical power it needs to operate. This is similar to a computer that won't turn on because it's not plugged in or the power supply has failed. A technician will need to check the small transformer that supplies this power and, if that is working, may need to replace the control board.

Diagnostic procedure

The full DS2 OFF / DS1 OFF procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
1) Check control transformer power (24V). 2) If power is available to control and LED(s) do not light, replace board.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock DS2 OFF / DS1 OFF procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of DS2 OFF / DS1 OFF

Ranked by how often they cause this code
  1. 1Failed control transformer
  2. 2Blown low-voltage fuse
  3. 3Open or disconnected wiring at R or C terminals
  4. 4Tripped or open secondary circuit breaker
  5. 5Failed control board

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about DS2 OFF / DS1 OFF

What does DS2 OFF / DS1 OFF mean on a Lennox heat_pump?
This error indicates that the control board is not receiving 24VAC power at its R and C control terminals. Both diagnostic LEDs go dark because the board has no power to operate them. The cause is either a loss of 24VAC from the control transformer or a complete failure of the control board itself. A technician will check for voltage at those terminals to determine which component is at fault.
Is it safe to continue running my Lennox heat pump with a DS2 OFF / DS1 OFF error?
The unit will not operate at all when this error is active because the control board has no power. There is no immediate safety hazard from the error itself, but do not attempt to bypass the control circuit to force operation. If the underlying cause is a short circuit or wiring fault, operating the system without correcting it could create a fire risk or cause further component damage.
Will resetting my Lennox heat pump clear the DS2 OFF / DS1 OFF error?
A simple reset will not clear this error because the control board has no power to process a reset command. The underlying power supply issue must be corrected before the board can initialize and restore normal operation. Once the transformer, fuse, wiring, or board is repaired or replaced and 24VAC is restored to the R and C terminals, the system should power up and resume normal diagnostics automatically.
How do I fix the DS2 OFF / DS1 OFF error on my Lennox heat pump?
Start by measuring voltage at the R and C terminals on the control board using a multimeter; you should see approximately 24VAC. If voltage is absent, inspect the control transformer, any low-voltage fuses, and the wiring between the transformer and the board. If 24VAC is present at the terminals but the board still shows no signs of life, the control board has failed and needs to be replaced.
How much does it cost to repair a DS2 OFF / DS1 OFF error on a Lennox heat pump?
Repair cost depends on the root cause. Replacing a blown low-voltage fuse is typically inexpensive, often under $50 including a service call. A failed control transformer replacement generally ranges from $150 to $350 depending on the model. If the control board itself has failed, parts and labor can range from $400 to $900 or more depending on the specific board and local labor rates.