Model reference
Lennox 50A93
Heat Pump
11 documents50 error codes6 service modes
Available documentation
Service Manual
- 14HPX Series Service Literature24 pg
- XP19 Series Service Literature27 pg
- HPXA16 Series23 pg
- HP13 SERIES UNITS Service Literature15 pg
- XP15 Series Service Literature21 pg
- 13HPX Series Service Literature20 pg
- HPXA12 Series Units - Service Literature23 pg
- XP14 Series Service Literature23 pg
- XP13 Series Service Literature16 pg
- XP16 Series Service Literature24 pg
- XPG20 Series Service Literature36 pg
MyPros+ Max
Diagnose your Lennox 50A93.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (50)
CodeMeaning
1Long Run Time2System Pressure Trip or Discharge Sensor Fault3Short Cycling4Locked Rotor5Open Circuit6Open Start Circuit7Open Run Circuit8Welded Contactor9Low VoltageAlternating FAST FlashCoil sensor problemAlternating FAST Flash (Green/Red)Coil sensor problemAlternating SLOW Flash5-minute anti-short cycle delay (initial power up, safety trip, or end of room…Alternating SLOW Flash (Green/Red)5-minute anti-short cycle delay after initial power up, safety trip, or end of…DS2 Alternating FAST Flash / DS1 Alternating FAST FlashCoil sensor problemDS2 Alternating SLOW Flash / DS1 Alternating SLOW Flash5-minute anti-short cycle delay due to initial power up, safety trip, or end of…DS2 OFF / DS1 OFFNo power (24V) to control terminals R & C or board failure.DS2 OFF / DS1 ONLow Pressure LOCKOUTDS2 OFF / DS1 SLOW FlashLow Pressure FaultDS2 ON / DS1 OFFHigh Pressure LOCKOUTDS2 ON / DS1 ONCircuit board failureDS2 Simultaneous FAST Flash / DS1 Simultaneous FAST FlashAmbient sensor problemDS2 Simultaneous SLOW Flash / DS1 Simultaneous SLOW FlashNormal operationDS2 SLOW Flash / DS1 OFFHigh Pressure FaultDS2:Alternating FAST Flash / DS1:Alternating FAST FlashCoil sensor problemDS2:Alternating SLOW Flash / DS1:Alternating SLOW Flash5-minute anti-short cycle delay due to initial power up, safety trip, or end of…DS2:FAST Flash / DS1:OFFDischarge sensor lockoutDS2:FAST Flash / DS1:ONDischarge line temperature lockoutDS2:OFF / DS1:FAST FlashDischarge sensor faultDS2:OFF / DS1:OFFNo power (24V) to board terminals R & C or board failure.DS2:OFF / DS1:ONLow pressure lockoutView all 50 error codes
DS2:OFF / DS1:SLOW FlashLow pressure faultDS2:ON / DS1:OFFHigh pressure lockoutDS2:ON / DS1:ONCircuit board failureDS2:Simultaneous FAST Flash / DS1:Simultaneous FAST FlashAmbient sensor problemDS2:Simultaneous SLOW Flash / DS1:Simultaneous SLOW FlashNormal operationDS2:SLOW Flash / DS1:OFFHigh pressure faultDS2:SLOW Flash / DS1:ONDischarge line temperature faultGreen FAST Flash / Red OFFDischarge sensor lockout (5 strikes)Green FAST Flash / Red ONDischarge line temperature lockout (5 strikes)Green OFF / Red FAST FlashDischarge sensor faultGreen OFF / Red SLOW FlashLow pressure faultGreen ON / Red OFFLow pressure lockout (5 strikes)Green ON / Red ONCircuit board failureGreen SLOW Flash / Red OFFHigh pressure faultGreen SLOW Flash / Red ONDischarge line temperature faultOFF/OFFNo power (24V) to board terminals R & C or board failure.Simultaneous FAST FlashAmbient sensor problemSimultaneous FAST Flash (Green/Red)Ambient sensor problemSimultaneous SLOW FlashNormal operationSimultaneous SLOW Flash (Green/Red)Normal operation
Service modes (6)
- 5-Strike Lockout Reset["Cycle OFF the 24-volt power to the control board (R terminal), then restore power.","OR short the…
- Compressor Modulation Operational Check["Turn main power OFF to outdoor unit.","Adjust room thermostat set point above (heating) or below…
- Compressor Two-Stage Modulation Operational Check["Turn main power OFF to outdoor unit.","Adjust room thermostat set point above (heating) or below…
- Defrost Board Test Mode["Ensure Y1 input is active (ON) and the O room thermostat terminal into board is inactive (heating…
- LSOM Installation Verification Test["Test 1 (Trip LED)
- Test Mode (Defrost Control)["Ensure Y1 is energized (active ON) and the O room thermostat terminal into the board is…
Full entry steps, exit procedures, and test sequences are available in Max.