Model reference

Lennox 50A93

Heat Pump

11 documents50 error codes6 service modes

Available documentation

Service Manual

  • 14HPX Series Service Literature24 pg
    Covers this model
  • XP19 Series Service Literature27 pg
    Covers this model
  • HPXA16 Series23 pg
    Covers this model
  • HP13 SERIES UNITS Service Literature15 pg
    Covers this model
  • XP15 Series Service Literature21 pg
    Covers this model
  • 13HPX Series Service Literature20 pg
    Covers this model
  • HPXA12 Series Units - Service Literature23 pg
    Covers this model
  • XP14 Series Service Literature23 pg
    Covers this model
  • XP13 Series Service Literature16 pg
    Covers this model
  • XP16 Series Service Literature24 pg
    Covers this model
  • XPG20 Series Service Literature36 pg
    Covers this model
MyPros+ Max

Diagnose your Lennox 50A93.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax

Error codes (50)

CodeMeaning
1Long Run Time2System Pressure Trip or Discharge Sensor Fault3Short Cycling4Locked Rotor5Open Circuit6Open Start Circuit7Open Run Circuit8Welded Contactor9Low VoltageAlternating FAST FlashCoil sensor problemAlternating FAST Flash (Green/Red)Coil sensor problemAlternating SLOW Flash5-minute anti-short cycle delay (initial power up, safety trip, or end of room…Alternating SLOW Flash (Green/Red)5-minute anti-short cycle delay after initial power up, safety trip, or end of…DS2 Alternating FAST Flash / DS1 Alternating FAST FlashCoil sensor problemDS2 Alternating SLOW Flash / DS1 Alternating SLOW Flash5-minute anti-short cycle delay due to initial power up, safety trip, or end of…DS2 OFF / DS1 OFFNo power (24V) to control terminals R & C or board failure.DS2 OFF / DS1 ONLow Pressure LOCKOUTDS2 OFF / DS1 SLOW FlashLow Pressure FaultDS2 ON / DS1 OFFHigh Pressure LOCKOUTDS2 ON / DS1 ONCircuit board failureDS2 Simultaneous FAST Flash / DS1 Simultaneous FAST FlashAmbient sensor problemDS2 Simultaneous SLOW Flash / DS1 Simultaneous SLOW FlashNormal operationDS2 SLOW Flash / DS1 OFFHigh Pressure FaultDS2:Alternating FAST Flash / DS1:Alternating FAST FlashCoil sensor problemDS2:Alternating SLOW Flash / DS1:Alternating SLOW Flash5-minute anti-short cycle delay due to initial power up, safety trip, or end of…DS2:FAST Flash / DS1:OFFDischarge sensor lockoutDS2:FAST Flash / DS1:ONDischarge line temperature lockoutDS2:OFF / DS1:FAST FlashDischarge sensor faultDS2:OFF / DS1:OFFNo power (24V) to board terminals R & C or board failure.DS2:OFF / DS1:ONLow pressure lockout
View all 50 error codes

Service modes (6)

  • 5-Strike Lockout Reset["Cycle OFF the 24-volt power to the control board (R terminal), then restore power.","OR short the…
  • Compressor Modulation Operational Check["Turn main power OFF to outdoor unit.","Adjust room thermostat set point above (heating) or below…
  • Compressor Two-Stage Modulation Operational Check["Turn main power OFF to outdoor unit.","Adjust room thermostat set point above (heating) or below…
  • Defrost Board Test Mode["Ensure Y1 input is active (ON) and the O room thermostat terminal into board is inactive (heating…
  • LSOM Installation Verification Test["Test 1 (Trip LED)
  • Test Mode (Defrost Control)["Ensure Y1 is energized (active ON) and the O room thermostat terminal into the board is…

Full entry steps, exit procedures, and test sequences are available in Max.

75,000+ service documents · 20,000+ error codes · 100+ brands

Get Started