Lennox Heat Pump Error Code DS2:SLOW Flash / DS1:ON
Discharge line temperature fault - discharge line temperature exceeded 285°F (140°C) during compressor operation; detects shorted sensor or high discharge temperatures.
SourceHeat Pump - Service Manual: XP16 Series Split-Systemp. 10
Diagnostic procedure
The full DS2:SLOW Flash / DS1:ON procedure
Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.
MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check discharge line sensor connections and resistance; check system charge and operating pressures; compressor will remain off until discharge temp drops below 225°F (107°C).
SourceHeat Pump - Service Manual: XP16 Series Split-Systemp. 10