What the Green SLOW Flash / Red ON error code actually means

Your Lennox heat pump shut off its compressor because the refrigerant line leaving the compressor got too hot, over 300 degrees Fahrenheit, which can cause serious internal damage if left running. The system is designed to wait until that line cools down before trying to restart. This is a protective shutdown, not a random glitch, and the underlying cause needs to be identified and corrected before the unit will run reliably again.

Diagnostic procedure

The full Green SLOW Flash / Red ON procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check system charge and airflow. Verify discharge sensor connection and placement.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock Green SLOW Flash / Red ON procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of Green SLOW Flash / Red ON

Ranked by how often they cause this code
  1. 1Low refrigerant charge
  2. 2Restricted airflow across indoor or outdoor coil
  3. 3Refrigerant overcharge
  4. 4Discharge temperature sensor fault or poor placement
  5. 5Failing compressor with low volumetric efficiency

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about Green SLOW Flash / Red ON

What does Green SLOW Flash / Red ON mean on a Lennox heat pump?
This code indicates a discharge line temperature fault. The refrigerant discharge line exiting the compressor exceeded 300°F (148°C), triggering an automatic compressor shutdown. The compressor will remain off until the discharge line temperature falls below 225°F (107°C). The fault is a protective response to an underlying system problem, most commonly related to refrigerant charge or airflow.
Is it safe to keep running my Lennox heat pump with a Green SLOW Flash / Red ON code?
The system has already shut down the compressor to protect itself, so it will not run normally in this condition. Attempting to force the unit back into operation without correcting the root cause risks permanent compressor damage. Leave the system in its protected state and schedule a service call promptly, especially during extreme weather when the heat pump is needed most.
How much does it cost to repair a Lennox heat pump with a discharge line temperature fault?
Repair costs vary widely depending on the root cause. A refrigerant recharge typically ranges from $150 to $450 depending on refrigerant type and the amount needed. Coil cleaning or sensor replacement generally falls in the $100 to $300 range for parts and labor. If the compressor itself has failed, replacement costs can range from $1,000 to $2,500 or more depending on the unit and labor rates in your area.
Can I fix a Green SLOW Flash / Red ON fault myself on a Lennox heat pump?
Some preliminary checks are within reach of a knowledgeable homeowner, such as inspecting and replacing air filters, clearing debris from the outdoor coil, and confirming airflow from supply registers. However, verifying refrigerant charge requires manifold gauges and EPA certification to handle refrigerants, so charge-related diagnosis and repair must be performed by a licensed HVAC technician. Sensor replacement and compressor evaluation also require professional service.
Will resetting the Lennox heat pump clear the Green SLOW Flash / Red ON code?
The compressor will automatically attempt to restart once the discharge line temperature drops below 225°F (107°C), so a manual hard reset is not always necessary to clear the lockout. However, if the underlying cause such as low charge or restricted airflow is not corrected, the fault will return quickly after the restart. A reset without diagnosis and repair is not a solution and can lead to repeated thermal stress on the compressor.