What the Green FAST Flash / Red OFF error code actually means

Your Lennox heat pump has shut itself down because a temperature sensor near the compressor reported bad readings five times in a row. The system locked out automatically to protect the compressor from running without reliable temperature monitoring. A technician will need to check or replace the sensor or its wiring to restore normal operation.

Diagnostic procedure

The full Green FAST Flash / Red OFF procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Cycle 24V power to board or short TEST pins 1-2 seconds to reset. Check/replace sensor harness.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock Green FAST Flash / Red OFF procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of Green FAST Flash / Red OFF

Ranked by how often they cause this code
  1. 1Damaged or corroded sensor harness
  2. 2Failed discharge temperature sensor (thermistor)
  3. 3Loose or disconnected connector at the sensor or board
  4. 4Actual high discharge temperature condition
  5. 5Faulty control board

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about Green FAST Flash / Red OFF

What does Green FAST Flash / Red OFF mean on a Lennox heat pump?
This flash pattern indicates a discharge sensor lockout. The control board detected five out-of-range readings from the discharge temperature sensor during a single Y1 demand cycle and locked out the system to protect the compressor. The fault can be caused by a faulty sensor, damaged wiring harness, or in some cases an actual extreme discharge temperature condition. The system will not restart automatically until the lockout is manually reset.
Is it safe to keep running my Lennox heat pump when it shows this error?
The system has already locked itself out, so the compressor is not running while this code is active. It is not safe to repeatedly reset the lockout and force the unit to run without diagnosing the root cause, because the discharge sensor is there to protect the compressor from damaging temperature extremes. Continued operation without a functioning sensor could result in compressor failure.
Will resetting the board permanently clear the Green FAST Flash / Red OFF code on a Lennox heat pump?
Resetting the board clears the current lockout and allows the system to run again, but it does not fix the underlying fault. If the discharge sensor or harness has not been repaired or replaced, the board will detect five more out-of-range readings during the next demand cycle and re-enter lockout. A permanent fix requires diagnosing and correcting the sensor circuit fault rather than relying on repeated resets.
How do I reset the Green FAST Flash / Red OFF lockout on my Lennox heat pump?
You can reset the lockout by cycling the 24-volt control power to the board or by shorting the TEST pins on the control board for one to two seconds. Either method clears the five-strike count and allows the system to attempt operation again. Keep in mind that if the underlying sensor or wiring fault is not corrected, the board will accumulate five more strikes during the next demand cycle and return to lockout.
How much does it cost to repair the Green FAST Flash / Red OFF error on a Lennox heat pump?
Repair costs vary depending on which component has failed. A sensor harness repair or connector cleaning may cost between $75 and $200 in labor. Replacing the discharge temperature sensor typically runs between $100 and $300 including parts and labor. A control board replacement, if required, can range from $400 to $800 or more depending on the model and labor rates in your area.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass