Lennox Heat Pump Error Code DS2 ON / DS1 OFF

High pressure lockout

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the DS2 ON / DS1 OFF error code actually means

Your Lennox heat pump shut itself down as a safety measure because an internal pressure sensor detected dangerously high pressure inside the system five separate times during one run cycle. This usually points to something blocking airflow over the coils, a fan that is not working correctly, or a refrigerant charge that is out of balance. A technician will need to diagnose and correct the underlying problem before the system can run again.

Diagnostic procedure

The full DS2 ON / DS1 OFF procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
1) Remove any blockages or restrictions from coils and/or fans; check indoor and outdoor fan motor for proper current draws. 2) Check system charge using approach & subcooling temperatures. 3) Check system operating pressures and compare to unit charging charts. 4) Make sure all pressure switches and sensors have secure connections.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock DS2 ON / DS1 OFF procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of DS2 ON / DS1 OFF

Ranked by how often they cause this code
  1. 1Blocked or dirty outdoor coils
  2. 2Outdoor or indoor fan motor failure
  3. 3Incorrect refrigerant charge
  4. 4Restricted indoor airflow
  5. 5Loose or faulty high pressure switch connections

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about DS2 ON / DS1 OFF

What does DS2 ON / DS1 OFF mean on a Lennox heat_pump?
This code means the system has entered a high pressure lockout because the high pressure switch tripped five times during a single Y1 demand cycle. The control board tracks each trip, and after the fifth occurrence it locks the system out to protect the compressor from damage. The lockout will not clear on its own and requires a technician to identify and correct the root cause before the unit can resume normal operation.
Is it safe to keep running my heat pump when this code is showing?
The system will not continue to run once it has entered lockout, which is the intended behavior. The lockout is a protective measure to prevent compressor damage from repeated high pressure events. Do not attempt to bypass or repeatedly reset the system without addressing the underlying cause, as doing so can damage the compressor and lead to a more costly repair.
How much does it cost to repair a Lennox heat pump showing a high pressure lockout?
Repair costs vary depending on the cause. Cleaning coils and clearing airflow obstructions is typically lower cost, often in the range of $100 to $250 including a service call. Refrigerant charge adjustment can run $150 to $400 depending on how much refrigerant is involved. Fan motor replacement generally falls between $200 and $600 depending on the motor and labor rates in your area. A full diagnosis from a licensed technician is the best way to get an accurate estimate.
Can I fix the DS2 ON / DS1 OFF error myself?
Some contributing factors can be addressed by a homeowner, such as replacing a dirty air filter, clearing debris from around the outdoor unit, and making sure supply and return registers are open and unobstructed. However, checking refrigerant charge, measuring fan motor current draws, and inspecting high pressure switch wiring all require proper tools and technical knowledge. A licensed HVAC technician should be contacted to fully diagnose and resolve the lockout condition.
Will resetting the unit clear the DS2 ON / DS1 OFF code?
A power cycle reset may temporarily clear the lockout and allow the unit to restart, but if the root cause is not corrected the high pressure switch will continue to trip and the lockout will return. Repeated resets without diagnosing the cause risk compressor damage. A proper repair addressing airflow, charge, or component issues is required for a lasting resolution.