Skip to main content
Error code reference
Lennox Heat Pump Error Code DS2:Alternating SLOW Flash / DS1:Alternating SLOW Flash
5-minute anti-short cycle delay due to initial power up, safety trip, or end of room thermostat demand.
SourceHeat Pump - Service Manual: XP16 Series Split-Systemp. 10
Diagnostic procedure
The full DS2:Alternating SLOW Flash / DS1:Alternating SLOW Flash procedure
Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.
MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
None required (Jumper TEST pins to override).
SourceHeat Pump - Service Manual: XP16 Series Split-Systemp. 10
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock DS2:Alternating SLOW Flash / DS1:Alternating SLOW Flash procedure $9.95
Or subscribe: $29/month for all codes plus Max diagnostics, with 70 Max messages a day. Plus applicable tax.
76,000+ service documents · 19,000+ error codes · 100+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax