Lennox Heat Pump Error Code Green FAST Flash / Red ON

Discharge line temperature lockout (5 strikes)

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the Green FAST Flash / Red ON error code actually means

Your Lennox heat pump has shut itself down because it detected dangerously high temperatures at the compressor outlet five times in a row. This is a protective measure to prevent the compressor from being seriously damaged. A technician will need to determine whether a faulty temperature sensor or an actual refrigerant problem is causing the repeated shutdowns.

Diagnostic procedure

The full Green FAST Flash / Red ON procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Cycle 24V power to board or short TEST pins 1-2 seconds to reset. Check discharge sensor and system operation.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock Green FAST Flash / Red ON procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of Green FAST Flash / Red ON

Ranked by how often they cause this code
  1. 1Low refrigerant charge
  2. 2Shorted discharge line temperature sensor
  3. 3Restricted or improperly sized metering device
  4. 4Dirty or blocked outdoor coil
  5. 5Failing compressor

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about Green FAST Flash / Red ON

What does Green FAST Flash / Red ON mean on a Lennox heat pump?
This code indicates a discharge line temperature lockout caused by five consecutive temperature faults during a single Y1 demand cycle. The control board detected either a shorted discharge line sensor or actual high discharge temperatures five times before triggering the lockout. The lockout is a protective measure to prevent compressor damage from sustained high-temperature operation.
Is it safe to keep resetting my Lennox heat pump when this code appears?
Repeatedly resetting the unit without fixing the underlying problem puts the compressor at risk. The lockout system exists specifically to prevent compressor failure from overheating, and bypassing it through repeated resets can shorten compressor life significantly. If the fault recurs after the first reset, the unit should remain off until a technician completes a proper diagnosis.
How much does it cost to repair a Lennox heat pump showing this fault?
Repair costs vary widely depending on the root cause. Replacing a faulty discharge line temperature sensor typically runs in the range of $150 to $350 including labor. Refrigerant recharge or leak repair can range from $200 to $600 or more depending on the refrigerant type and amount needed. Compressor replacement is the most expensive scenario, often ranging from $1,200 to $2,500 or higher depending on the unit size and local labor rates.
Will resetting the board clear this lockout permanently?
Resetting by cycling 24V power or shorting the TEST pins for 1 to 2 seconds will clear the strike count and allow the unit to operate again, but the lockout will return if the underlying problem is not corrected. Each new Y1 demand cycle starts a fresh strike count, so a marginal system may take a few cycles before locking out again. The root cause, whether a faulty sensor or a refrigerant system issue, must be diagnosed and repaired for the lockout to stop recurring.
How do I diagnose whether the problem is the sensor or the refrigerant system?
Start by checking the resistance of the discharge line temperature sensor and comparing it to the rated specification for your model. A shorted sensor will read near zero ohms or significantly below the expected value at a known temperature. If the sensor checks out within spec, connect refrigerant manifold gauges and evaluate system pressures during operation to identify low charge, restriction, or compressor issues.