Lennox Heat Pump Error Code DS2:OFF / DS1:SLOW Flash
Low pressure fault - one strike counted on the low pressure switch trip counter.
SourceHeat Pump - Service Manual: XP16 Series Split-Systemp. 10
Diagnostic procedure
The full DS2:OFF / DS1:SLOW Flash procedure
Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.
MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Remove blockages or restrictions from coils and fans; check indoor and outdoor fan motor current draws; check system charge using approach and subcooling temperatures; check system operating pressures.