Lennox Heat Pump Error Code DS2:OFF / DS1:ON

Low pressure lockout

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the DS2:OFF / DS1:ON error code actually means

Your Lennox heat pump detected low refrigerant pressure too many times in a row during a single heating or cooling cycle and shut itself down to prevent damage to the compressor. This is usually caused by a refrigerant leak, blocked airflow, or a faulty pressure sensor. The system will need a professional inspection to find and correct the root cause before it will operate normally again.

Diagnostic procedure

The full DS2:OFF / DS1:ON procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Remove blockages from coils/fans, check system charge using approach and subcooling, check operating pressures, verify pressure switch connections.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock DS2:OFF / DS1:ON procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of DS2:OFF / DS1:ON

Ranked by how often they cause this code
  1. 1Low refrigerant charge due to a leak
  2. 2Blocked or restricted coil and fan airflow
  3. 3Faulty or incorrectly wired low pressure switch
  4. 4Failed or restricted metering device
  5. 5Extremely low ambient outdoor temperature

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about DS2:OFF / DS1:ON

What does DS2:OFF / DS1:ON mean on a Lennox heat pump?
This code indicates a low pressure lockout. The heat pump's control board detected five separate low pressure faults during a single thermostat demand cycle (Y1), meaning the low pressure switch opened five times before the call for heating or cooling was satisfied. The system locks out the compressor at this point to prevent damage from running with insufficient refrigerant pressure.
Is it safe to keep running my Lennox heat pump with this fault code active?
The lockout is a protective function, so the compressor will not run while the fault is active. Attempting to repeatedly reset and restart the system without correcting the cause can accelerate compressor wear if the unit runs even briefly under low-pressure conditions. It is best to leave the system off until a technician can diagnose and repair the fault.
How do technicians diagnose the cause of the low pressure lockout on a Lennox heat pump?
Diagnosis starts with a visual inspection of both the indoor and outdoor coils and fans for blockages, ice buildup, or collapsed filters. The technician then connects gauge manifolds to measure operating suction and discharge pressures, and cross-references those readings with approach temperature and subcooling values to assess system charge. Wiring and operation of the low pressure switch are also verified. If pressures are low, a leak search is performed before any refrigerant is added to the system.
Can I reset the DS2:OFF / DS1:ON lockout myself and will it fix the problem?
You can reset the lockout by cycling power to the unit, but this will not resolve the underlying cause. If the root problem, such as low refrigerant, blocked coils, or a faulty pressure switch, is not corrected, the system will accumulate five more low pressure faults and lock out again. A full diagnosis of operating pressures, airflow, and system charge is necessary before the unit will run reliably.
What does it cost to repair the DS2:OFF / DS1:ON low pressure lockout fault?
Repair costs vary significantly depending on the root cause. Clearing a blocked coil or replacing a low pressure switch typically costs in the range of $100 to $300 for labor and parts. If a refrigerant leak is involved, leak detection, repair, and recharge can range from $300 to $800 or more depending on the leak location and refrigerant type. A failed metering device replacement may fall in the $250 to $600 range including labor.