Lennox Heat Pump Error Code DS2 SLOW Flash / DS1 OFF

High Pressure Fault

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the DS2 SLOW Flash / DS1 OFF error code actually means

Your Lennox heat pump detected that the pressure inside part of the refrigerant system got too high, which is a safety concern the unit is designed to catch and log. This can happen because airflow is blocked somewhere, the refrigerant charge is off, or a fan is not working properly. The system added one mark to its fault log, and if this keeps happening it may shut down completely until a technician clears the fault.

Diagnostic procedure

The full DS2 SLOW Flash / DS1 OFF procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
1. Remove blockages/restrictions from coils and fans; check indoor and outdoor fan motor current draws. 2. Check system charge using approach & subcooling temperatures. 3. Check system operating pressures and compare to charging charts. 4. Verify all pressure switches and sensors have secure connections.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock DS2 SLOW Flash / DS1 OFF procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of DS2 SLOW Flash / DS1 OFF

Ranked by how often they cause this code
  1. 1Blocked or dirty outdoor condenser coils
  2. 2Outdoor or indoor fan motor failure or reduced airflow
  3. 3Refrigerant overcharge
  4. 4Restricted indoor airflow
  5. 5Loose or faulty high pressure switch connection

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about DS2 SLOW Flash / DS1 OFF

What does DS2 SLOW Flash / DS1 OFF mean on a Lennox heat_pump?
This code indicates a High Pressure Fault, meaning the unit detected refrigerant pressure exceeding a safe limit on the high side of the system. Each occurrence adds one strike to the high pressure fault counter tracked by the control board. Common triggers include blocked coils, fan problems, and incorrect refrigerant charge. If the fault accumulates enough strikes, the unit may enter a lockout state.
Is it safe to keep running my Lennox heat pump when this code appears?
The high pressure safety switch is designed to protect the compressor from damaging pressure levels, so the fault should not be ignored. Continued operation without identifying and correcting the root cause can stress the compressor and refrigerant circuit components. It is best to address the fault promptly, and if the unit is tripping this code repeatedly, shut it down until the cause is diagnosed.
How much does it cost to repair a high pressure fault on a Lennox heat pump?
Repair costs vary widely depending on the root cause. Cleaning coils or replacing an air filter may cost very little, while fan motor replacement typically runs in the range of $200 to $600 including labor. Refrigerant-related repairs such as recovering and recharging the system can range from $150 to $500 or more depending on refrigerant type and the amount needed. A service call for diagnosis alone generally falls in the $75 to $150 range.
Can I fix a DS2 Slow Flash high pressure fault myself?
Some causes are accessible to a knowledgeable DIYer, such as clearing debris from outdoor coils, replacing a dirty air filter, or confirming fan operation. However, diagnosing refrigerant charge issues, measuring system pressures against charging charts, and recovering or adding refrigerant require EPA Section 608 certification and gauges. If basic airflow checks do not resolve the fault, a licensed HVAC technician should evaluate the refrigerant circuit.
Will resetting the Lennox heat pump clear this fault code?
A reset may clear the current display and allow the unit to restart, but the fault counter on the control board retains the strike count. If the underlying cause of the high pressure condition is not corrected, the fault will recur and additional strikes will accumulate. Repeated resets without repairs can lead to a full lockout requiring a technician to manually clear the board.