Samsung Heat Pump Error Code E130

COND MID temperature sensor error (open/short) on outdoor unit heat exchanger.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the E130 error code actually means

Your Samsung heat pump is showing an error because one of its temperature sensors on the outdoor unit has stopped working correctly. The system detected that the sensor is either disconnected or damaged, so it shut down to avoid running without accurate temperature information. A technician will need to inspect and likely replace the sensor or repair its wiring connection.

Diagnostic procedure

The full E130 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check if outdoor unit COND MID sensor connector is separated from PCB; reconnect if so.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E130 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E130

Ranked by how often they cause this code
  1. 1Disconnected sensor connector at outdoor PCB
  2. 2Failed thermistor (open circuit)
  3. 3Shorted thermistor
  4. 4Damaged wiring harness
  5. 5Corrosion at connector pins

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E130

What does E130 mean on a Samsung heat pump?
E130 indicates a fault with the COND MID temperature sensor on the outdoor unit heat exchanger. The system has detected that the sensor circuit is either open or short-circuited, meaning the signal is outside the normal thermistor range. The heat pump typically stops operation when this error is active to prevent running without accurate condenser temperature data.
Is it safe to run my heat pump while E130 is displayed?
In most cases the system will not operate normally while E130 is active, which is a built-in protection measure. Attempting to override or reset the unit repeatedly without resolving the underlying sensor fault is not recommended, as the control system relies on the COND MID reading to prevent overheating or inefficient operation of the refrigerant circuit.
Will resetting the heat pump clear the E130 error?
A power reset may temporarily clear the error code display, but if the underlying sensor fault, such as a failed thermistor or damaged wire, still exists, the E130 code will return once the system attempts to read the sensor again. A reset is useful for confirming whether a loose connector was the cause after reseating it, but it is not a fix on its own.
Can I fix the E130 error myself?
If you are comfortable working around electrical components, you can start by checking whether the COND MID sensor connector on the outdoor unit PCB is loose or disconnected and reseating it firmly. If the connector is secure and the error persists, measuring the thermistor resistance and inspecting the wiring harness for damage will require basic electrical knowledge and a multimeter. Full sensor replacement and PCB diagnosis are best handled by a qualified technician.
How much does it cost to repair a Samsung heat pump E130 error?
Repair costs vary depending on the root cause. If only the connector needs reseating, a service call fee may be the primary expense, typically ranging from $75 to $150. Replacing the COND MID thermistor sensor, including parts and labor, generally falls in the $100 to $300 range. If the outdoor unit PCB is also damaged, costs can increase significantly.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass