mypros+
Error code reference

Samsung Heat Pump Error Code E145

Compressor sump temperature protection control

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the E145 error code actually means

The E145 code means the bottom of the compressor, which is the heart of the heat pump, got too hot for too long. The system shut itself down to prevent serious internal damage. A technician needs to find out why the compressor was running so hot, which could be a refrigerant issue, blocked airflow, or a faulty internal component.

Diagnostic procedure

The full E145 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Error reset (Key 3), connect S-net, perform test operation under same conditions, check digital compressor loading/unloading operation.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E145 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E145

Ranked by how often they cause this code
  1. 1Digital compressor loading solenoid stuck in fully loaded position
  2. 2Low refrigerant charge
  3. 3Restricted airflow across the heat exchanger
  4. 4Faulty sump temperature sensor reporting inaccurate readings
  5. 5Refrigerant overcharge or non-condensable contamination

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E145

What does E145 mean on a Samsung heat pump?
E145 indicates that the compressor sump temperature exceeded 95 degrees Celsius for more than 5 minutes, triggering the thermal protection shutdown. The sump is the oil reservoir at the base of the compressor. The system shuts down at this threshold to prevent oil breakdown and compressor damage. A technician should connect Samsung S-net diagnostics and perform a test operation to identify the underlying cause.
Is it safe to keep running my Samsung heat pump when the E145 code appears?
No, it is not safe to force the system to run continuously while E145 is active. The code exists to protect the compressor from heat-related oil degradation and mechanical damage. Continued operation without addressing the cause can lead to complete compressor failure, which is a significantly more expensive repair than resolving the original issue.
What should a technician check first when diagnosing E145 on a Samsung heat pump?
After performing an error reset with Key 3, the technician should connect S-net to access live system data and run a test operation under the same conditions that caused the fault. The priority check is the digital compressor loading and unloading operation, specifically whether the solenoid is cycling the compressor between loaded and unloaded states as designed. Refrigerant pressures and airflow conditions should also be evaluated during the test run.
Will resetting the E145 error fix the problem on my Samsung heat pump?
A reset using Key 3 will clear the fault and allow the system to restart, but it will not fix the underlying cause. If the conditions that triggered E145 have not changed, the fault will return. The reset is the first step in diagnostics, used to observe whether the issue recurs under the same operating conditions so the root cause can be identified.
How much does it cost to repair a Samsung heat pump showing error E145?
Repair costs depend entirely on the root cause. If the fix involves cleaning coils, recharging refrigerant, or adjusting airflow, costs may range from around 150 to 400 dollars. If the digital compressor loading solenoid needs replacement, costs typically range from 300 to 700 dollars. A full compressor replacement, if damage has already occurred, can range from 1,200 to 2,500 dollars or more including labor.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass