Samsung Heat Pump Error Code E485

Fixed compressor 1 discharge temperature sensor breakaway

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the E485 error code actually means

Your Samsung heat pump is detecting that the temperature sensor on the main compressor's hot refrigerant outlet line is either loose, disconnected, or faulty. The system noticed that the compressor is running but the temperature reading from that sensor does not match what it should be at the current operating pressure. This usually means the sensor has come loose from its holder on the pipe or the sensor itself has failed.

Diagnostic procedure

The full E485 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check if emission temperature sensor and holder are correctly attached; measure resistance.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E485 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E485

Ranked by how often they cause this code
  1. 1Sensor physically detached from holder
  2. 2Failed or out-of-range discharge temperature sensor
  3. 3Loose or corroded sensor wiring connection
  4. 4Damaged sensor holder or mounting bracket
  5. 5Refrigerant charge or pressure issue causing abnormal saturation temperature

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E485

What does E485 mean on a Samsung heat pump?
E485 indicates a fixed compressor 1 discharge temperature sensor breakaway fault. The system detected that the CT sensor was reading over 5A (confirming the compressor is running) while the discharge temperature sensor read below the high pressure saturation temperature for more than 30 minutes. This combination tells the control board that the discharge sensor is either physically detached from the discharge line or has failed electrically.
Will resetting the heat pump clear the E485 error?
A power reset may temporarily clear the fault display, but E485 will return if the underlying condition is not corrected. The fault requires the CT sensor to read over 5A and the discharge temperature to remain below saturation temperature for over 30 minutes, so if the sensor is still loose or failed, the error will reappear once the compressor has run long enough to retrigger the timer. Address the sensor attachment and condition before relying on a reset.
How much does it typically cost to repair an E485 fault on a Samsung heat pump?
If the repair only requires reseating the sensor in its holder with no parts needed, the cost is primarily a service call fee, typically in the range of $75 to $150. If the discharge temperature sensor itself needs replacement, parts and labor combined generally fall in the range of $150 to $400 depending on the specific model and local labor rates. If the fault is related to a refrigerant charge issue requiring recovery, recharge, and leak diagnosis, costs can be higher.
Can I fix E485 myself or do I need a technician?
The first diagnostic step, checking that the discharge temperature sensor is correctly seated in its holder and measuring its resistance, is something a knowledgeable DIYer can perform with a multimeter. However, if the fault involves refrigerant pressure issues, sensor replacement on the discharge line, or accessing internal heat pump components, a certified HVAC technician should handle the repair. Working around refrigerant circuits and high-voltage compressor wiring carries significant safety risks.
Is it safe to keep running the heat pump with an E485 code active?
Continuing to operate the heat pump with E485 active is not recommended. The discharge temperature sensor is a critical protection input for compressor 1. If the sensor has truly failed or lost contact, the system loses the ability to detect an overheating condition at the compressor discharge, which can allow damaging temperatures to go undetected and potentially cause compressor failure. Shut the unit down and diagnose the sensor before resuming normal operation.