Samsung Range Error Code -tE-
Sub PCB communication error
Sub PCB communication error — communication failure between Sub PCB and Touch glass.
First step from the service manual
Check whether connector TE201 of Sub PCB has been inserted.
The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.
Get the full diagnostic procedure for -tE-.
- Step-by-step tests with expected resistance, voltage, and continuity values
- Wiring diagram references and connector pinouts from the OEM service manual
- Verified part numbers when replacement is required
$29/month · Cancel anytime · Or $9.95 3-day pass
What -tE- means on a Samsung range
The -tE- error code on a Samsung range indicates a communication failure between the Sub PCB (printed circuit board) and the touch glass panel. The Sub PCB serves as an intermediary controller that manages the touch interface, relaying input signals from the touch glass to the main control board. When this communication link breaks down, the range cannot process touch commands, and the error is triggered to alert the user and technician that data is not passing correctly between these two components.
The most common starting point for diagnosing this error is connector TE201 on the Sub PCB. This connector is the physical interface that links the Sub PCB to the touch glass assembly. If this connector is loose, partially seated, or has been displaced due to vibration or prior disassembly, communication will be interrupted and the -tE- code will appear. Inspecting and firmly reseating TE201 is always the first step before assuming component failure.
If the connector is properly seated and the error persists, the fault may lie with the wiring harness running between the Sub PCB and the touch glass, the touch glass itself, or the Sub PCB. Damaged wire insulation, corroded connector pins, or a failed touch glass digitizer can all prevent the signal from transmitting correctly. In some cases the Sub PCB itself may have failed and will need replacement to restore proper communication.
Source: manufacturer service documentation.
Common causes of -tE-
- 01
Loose or unseated connector TE201
Wiring / connectionConnector TE201 on the Sub PCB is the primary link between the Sub PCB and the touch glass. If this connector is not fully inserted, communication fails immediately and the -tE- code appears. Inspect and firmly reseat the connector as the first diagnostic step.
- 02
Damaged or faulty wiring harness
Part replacementThe wiring harness connecting the Sub PCB to the touch glass can develop breaks, pinched wires, or corroded pins over time. Visually inspect the harness for any signs of wear, heat damage, or bent terminals at each connector end.
- 03
Failed touch glass assembly
Part replacementIf the touch glass digitizer has failed internally, it will not send or receive signals from the Sub PCB, triggering the communication error. Swapping the touch glass is required to confirm this as the cause.
- 04
Defective Sub PCB
Part replacementIf the connector and wiring check out correctly but the error remains, the Sub PCB itself may have failed. A faulty Sub PCB cannot maintain the communication protocol with the touch glass and will need to be replaced.
Frequently asked questions about -tE-
What does -tE- mean on a Samsung range?
Can I fix the -tE- error on my Samsung range myself?
Is it safe to use my Samsung range while the -tE- error is showing?
Will resetting my Samsung range clear the -tE- error?
How much does it cost to repair a Samsung range -tE- error?
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass