Samsung Refrigerator Error Code F-EVAP SENSOR

Freezer evaporator sensor disorder

Freezer evaporator sensor disorder — OPEN (sensing below -50°C) or SHORT (sensing above +50°C), indicated when MICOM input voltage is outside 0.5V–4.5V range.

First step from the service manual

Turn main power OFF then ON to run self-diagnosis check; inspect F-EVAP SENSOR wiring, connector, and resistance/voltage per temperature table.

The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.