Vision Washer Error Code dr:06
NTC-relay failure
NTC-relay failure – NTC is too hot.
First step from the service manual
Wait a couple of minutes.
The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.
Get the full diagnostic procedure for dr:06.
- Step-by-step tests with expected resistance, voltage, and continuity values
- Wiring diagram references and connector pinouts from the OEM service manual
- Verified part numbers when replacement is required
$29/month · Cancel anytime · Or $9.95 3-day pass
What dr:06 means on a Vision washer
The dr:06 error code on a Vision washer indicates an NTC relay failure caused by the NTC (Negative Temperature Coefficient) thermistor detecting an overtemperature condition. The NTC thermistor is a resistance-based temperature sensing component whose electrical resistance decreases as temperature rises. When the thermistor reads a temperature beyond the acceptable threshold for safe operation, the control board triggers this fault code to protect internal components from heat damage.
This fault is tied directly to the thermal monitoring circuit within the washer. The NTC thermistor continuously reports temperature data to the main control board during operation. If the sensed temperature climbs too high, the board interprets this as a relay failure condition rather than a normal operating state, halting the cycle to prevent further heat buildup or component damage. The root cause may be an actual overtemperature event, a faulty thermistor sending incorrect high readings, or a failure in the relay circuit that controls heating.
Because the first recommended diagnostic step is simply to wait a couple of minutes, the fault may clear on its own once the component cools to an acceptable range. This suggests thermal overshoot during a wash or dry cycle is a common trigger. If the code returns immediately or persists after cooling, further investigation of the NTC thermistor, its wiring, and the associated relay circuit will be necessary.
Source: manufacturer service documentation.
Common causes of dr:06
- 01
Temporary overheating during cycle
Wiring / connectionThe washer may have experienced a brief thermal spike during a heavy or extended cycle. Waiting a few minutes allows the component to cool and the error to clear on its own.
- 02
Faulty NTC thermistor
Part replacementA defective NTC thermistor can send inaccurate high-temperature readings to the control board even when no actual overheating is present. If the error returns quickly after cooling, the thermistor likely needs replacement.
- 03
NTC thermistor wiring or connection issue
Wiring / connectionLoose, corroded, or damaged wiring between the NTC thermistor and the control board can cause erratic resistance readings that mimic an overtemperature condition. Inspect the connector and wiring harness for visible damage or poor contact.
- 04
Relay circuit failure
Part replacementThe relay associated with the NTC thermal protection circuit may have failed, preventing the circuit from operating correctly even if the thermistor itself is functional. A failed relay will typically require board-level repair or replacement.
- 05
Poor ventilation or blocked airflow
Wiring / connectionIf the washer is installed in a confined space with restricted airflow, internal temperatures can build up faster than normal. Check that the installation area is adequately ventilated and that vents or openings on the unit are not obstructed.
Frequently asked questions about dr:06
What does dr:06 mean on a Vision washer?
Can I fix the dr:06 error myself, or do I need a technician?
Is it safe to keep using my Vision washer when the dr:06 code appears?
Will resetting my Vision washer clear the dr:06 error?
How much does it cost to repair a Vision washer with a dr:06 error?
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass