Model reference
Amana 108-2D
Air Conditioner
12 error codes15 service modes
MyPros+ Max
Diagnose your Amana 108-2D.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (12)
CodeMeaning
:Flashing colon indicates a power failure has occurred.Enter clockPower failure indication; 'Enter clock' flashes on display.F1E4Microwave ACU PCBA failure.F2Touch panel failure.F2E1Touch panel failure.F3HHumidity sensor failure.F4E1Cavity temperature sensor failure.F4E4Humidity sensor error.F6MW relay failure.F8E5Exhaust air temperature detection failure.NTC OPEN, CALL FOR SERVICEHF NTC thermistor is open circuit.NTC SHORT, CALL FOR SERVICEHF NTC thermistor is shorted.Service modes (15)
- Cavity Temperature Sensor Check["Press CANCEL
- Diagnostic / Test Mode["Plug in microwave oven or reconnect power.","Press CANCEL button to reach Standby mode (colon ':'…
- Diagnostic Test Mode["Plug in microwave oven or reconnect power.","Press CANCEL to enter Standby mode (colon ':'…
- Diagnostics / Test Mode["Plug in microwave oven or reconnect power.","Press CANCEL to reach standby (colon ':'…
- Exhaust Air Temperature Sensor Check["Press CANCEL
- Humidity Sensor Check["Press CANCEL
- Self-Diagnostic Test Mode["Press and hold the CANCEL/OFF button while opening the door.","While still holding the CANCEL/OFF…
- Sensor reading check (Cavity temperature sensor)["Press CANCEL
- Sensor reading check (Exhaust air temperature sensor)["Press CANCEL
- Sensor reading check (Humidity sensor)["Press CANCEL
- Sensor reading check (NTC sensor)["Press CANCEL
- Software version display["In Test mode, press Start/Add 30 Sec to display UI SW, ACU PCBA SW, and Gee version (format
- Touch Panel and ACU PCBA Test (Diagnostic Test Mode)["Plug in microwave oven or reconnect power and press the Cancel keypad to standby (colon…
- Touch Panel and ACU PCBA Test (Diagnostic/Test Mode)["Plug in microwave oven or reconnect power and press the Cancel keypad to standby (colon…
- Touch Panel and PCBA Self-Diagnostic Test Mode["Plug in microwave oven or reconnect power.","Press CANCEL button to enter standby (colon…
Full entry steps, exit procedures, and test sequences are available in Max.