Error codes (67)
CodeMeaning
dLLid Lock FailuredULid Unlock FailureE1Thermistor is open (open circuit detected).E2Thermistor has shorted (short circuit detected).E3User interface keyswitch or software mismatch between the control…F 1Pressure Signal Out-of-RangeF 2Keypad/User Interface FailureF 40ATC Thermistor Open/ShortF 41Motor RPS Thermistor Open/ShortF 42Heater in unknown stateF 43Heater is continuously ONF 44Heater cannot be turned ONF 50Motor StalledF 51Motor RPS FailureF 52Motor Stop FailureF 53Motor Control OvertempF 54Motor Control OvercurrentF 72Basket Re-engagement FailureF1Pressure Signal Out-of-RangeF1E1ACU errorF1E2Motor control errorF2Keypad/User Interface FailureF2E1Indicates a stuck button (depressed for over 20 seconds) or UI mismatch; only…F2E3Unsupported cycleF3E1Water level sensor errorF3E2Temperature sensor errorF3E3Inlet thermistor is open or shorted (open if temp drops below 18°F / >245k…F3E4Inlet thermistor has shorted; temperature above 391°F (<328 ohms).F3E5Second moisture sensor strip is open or shorted (Quad Sense models only; only…F3E6Moisture sensor strip is open; only appears in service diagnostic mode.View all 67 error codes
F3E7Moisture sensor strip has shorted; only appears in service diagnostic mode.F40ATC Thermistor Open/ShortF41Motor RPS Thermistor Open/ShortF4E0Heater is not detectedF4E1No voltage detected at the heater relay; only appears in Diagnostic Test Mode.F4E3Restricted/low air flow that may affect dryer performance.F4E4Low L2 voltage (less than 50V) detected at the CCU.F50Motor StalledF51Motor RPS FailureF52Motor Stop FailureF53Motor Control OvertempF54Motor Control OvercurrentF5E1Door switch errorF5E4Door not opened between cyclesF6E1ACU and HMI have not communicated for a specified amount of time.F6E2Communication error UI to ACUF6E3Communication error ACU to UIF72Basket Re-engagement FailureF7E2Motor drive circuit over temperatureF7E8Motor over temperatureF8E0Steam inlet valve error (not available on all models)F8E1No water detected entering washer or water level sensor trip not detectedF8E3Overflow conditionF9E1Long drainFCE1WiFi Module communications lost.HCHot, Cold ReversedL2Low L2 voltage (less than 50V) detected at the CCU.LdLong DrainLFLong FilllidOpen/Close LidoLOverloadedPFPower failure occurred while the dryer was running.PoPump OutrLLoad detected during the washer cleaning cycle (saved as F0E1)SdSuds DetectionSudSuds detecteduLUnbalanced Load
Service modes (23)
- Automatic Diagnostic Test Mode["Ensure washer is not currently running a cycle (in-progress screen should not be…
- automatic_diagnostic1
- Component Activation / Quick Service Cycle (LCD in Door Models)["Enter Service Diagnostic Mode (LCD in Door) first.","From the DIAGNOSTICS HOME screen, scroll…
- Console and Indicators Diagnostic Test Mode["Ensure washer is not currently running a cycle and LCD is on.","Press the Power/Cancel button and…
- console_and_indicators_diagnostic1. Plug in washer or reconnect power. 2. From Standby (Off) Mode, press and release the following…
- Customer-Focused Dryness Level Adjustment["In standby mode (dryer plugged in but not powered up), press and hold the DRYNESS LEVEL button…
- Diagnostic Test Mode["Unit must be in Standby mode (plugged in, display off).","Alternately press the Less Time (∨) and…
- Fault/Error Code Display["Enter Service Diagnostic Mode first.","Press and release the 3rd button used to activate Service…
- Install Diagnostics["Activate Service Diagnostic Mode first.","Press and release the 2nd button used to activate…
- Key Activation & Encoder Test (Console Models)["Activate Service Diagnostic Mode first.","Press and release the 1st button used to activate…
- Loads Test Mode["Ensure dryer is in standby mode (plugged in with all indicators off).","Within 5 seconds: Press…
- Manual Diagnostic Test Mode["Read and perform steps 1 and 2 of Activation of Automatic Diagnostic Test Mode (enter Service…
- manual_diagnostic1
- Pressure Transducer Calibration["Enter Manual Diagnostic Test Mode.","From the Component Activation screen, select the 'Pressure'…
- Quick Diagnostic Test["Enter Service Diagnostic Mode first.","Press and release the 2nd button used to activate Service…
- Saved Fault Codes["Enter Service Mode (Sound and Display > Service Mode > 5, 6, 5, 6 > Enter).","From the Diagnostic…
- Service Diagnostic Mode["Ensure washer is in standby mode (plugged in with all indicators off).","Select any three (3)…
- Service Diagnostic Mode (Console Models)["Ensure the dryer is in standby mode (plugged in with all indicators off).","Select any three (3)…
- Service Diagnostic Mode (LCD in Door Models)["Ensure the dryer is in standby mode (plugged in with all indicators off).","Open and close the…
- Service Test Mode (Console Models)["Activate Service Diagnostic Mode first.","Press and release the 2nd button used to activate…
- Software Version Display["Enter Service Diagnostic Mode first.","Press and hold the 2nd button used to activate Service…
- Software Version Display (Console Models)["Activate Service Diagnostic Mode first.","Press and hold the 2nd button used to activate Service…
- User Interface Test["Enter Service Diagnostic Mode first.","Press and release the 1st button used to activate Service…