Model reference
Amana OU-150-UA
Furnace
1 document61 error codes14 service modes
Available documentation
Tech Sheet
- Tech Sheet - W11597123 - Rev A2 pg
MyPros+ Max
Diagnose your Amana OU-150-UA.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (61)
CodeMeaning
:Flashing colon indicates a power failure has occurred.F0E1Load detected in drum during Clean Washer cycle.F0E2OversudsF0E4High temperature error during wash cycle.F0E5Off balance load detected.f1 e1Primary control failure.F1.E1Relay control board defective.F1E0EEPROM communication error.F1E1Main relay open or shorted.F1E2MCU over- or under-voltage error.F1E4Microwave relay failure (Relay 4903 on PCBA).F1E5Sensor out of range.F1E7PCB thermistor open or shorted.F2Touch panel failure.f2 e1Stuck button or user interface mismatch (only appears in service diagnostic…F2.H1Hood keys stuck.F2.H2Hood/light switch defective.F2.Q1Not reading keypad inputs.F2E0Keypad disconnected.F2E1Touch panel failure.F2E2Cancel key error.f3 e1Exhaust thermistor is open.f3 e2Exhaust thermistor has shorted.f3 e6Moisture sensor strip is open (only appears in service diagnostic mode).f3 e7Moisture sensor strip has shorted (only appears in service diagnostic mode).F3.H1Humidity sensor failure.F3.T1UIB (user interface board) thermistor failure.F3.T2FC (forced convection) thermistor failure.F3.T4Magnetron thermistor failure.F3E0Main sensor open or shorted.View all 61 error codes
F3E1Pressure sensor signal missing or out of range.F3E2Wash NTC (thermistor) open or shorted.F3E5Dry NTC faultF3E6Accelerometer error.F4E1Wash heater relay error or no feedback signalF4E2Wash heater relay error.F5E0Door and switches do not agree (Clean modeF5E2Door lock failure.F5E3Door unlock failure.F5E4Door not open error.F6MW (microwave) relay failure.F6E1No communication from the HMI detected by ACU.F6E2No communication from the ACU detected by the HMI.F6E3No communication from the MCU detected by the ACU.F7Power to magnetron interrupted.F7E10Motor disconnected error.F7E12MC/MCU overload.F7E2MC/MCU over temperature error or over current error/internal failure.F7E8MC/Motor over temperature error.F7E9Motor will not turn (locked rotor).F7EAMotor disconnected error (alternate hex display of F7E10).F7ECMC/MCU overload (alternate hex display of F7E12).f8 e1No voltage detected at the water valve relay (steam models only, only appears…F8E1Water inlet valve failure.F8E3Overflow condition detected.F9Relay control board communications error.F9.QTouch communication error between UIB and touch panel board.F9E1Long drainNTC OPEN, CALL FOR SERVICEHF NTC thermistor is open.NTC SHORT, CALL FOR SERVICEHF NTC thermistor is shorted.pfPower failure occurred while the dryer was running.
Service modes (14)
- Customer-Focused Drying Mode Adjustment1
- demo_mode["On the Main Menu, touch 'Settings & Info.'","On Settings & Info screen, touch 'Demo Mode.'","The…
- diagnostic["Unplug microwave oven or disconnect power.","Open the microwave oven door.","Press and hold…
- Diagnostics / Auto Test1. Press CANCEL > CANCEL > START to enter Diagnostics mode. 2. Press the 'up' arrow, the '+' (plus)…
- Fault/Error Code Display["Enter Service Diagnostic Mode
- Human-Machine Interface Test["First activate Service Diagnostic Mode.","Press and release the 1st button used to activate…
- learning_mode["Oven must be off.","On the Main Menu, touch 'Settings & Info.'","On Settings & Info screen, touch…
- Quick Diagnostic Test["First activate Service Diagnostic Mode.","Press and release the 2nd button used to activate…
- Self-Diagnostic Test Mode["Plug in microwave oven or reconnect power.","Press CANCEL button to enter standby (display shows…
- Self-diagnostic test mode (Touch Panel and PCBA Test)["Press and hold the OFF/CANCEL button while opening the door.","While still holding the OFF/CANCEL…
- Service Diagnostic Mode["Ensure washer is in standby mode (plugged in with all indicators off).","Wait 30 seconds after…
- Software Version Display["First activate Service Diagnostic Mode.","Press and hold the 2nd button used to activate Service…
- Touch Panel and PCBA Self-Diagnostic Test Mode["Press and hold the OFF/CANCEL button while opening the door.","While still holding the OFF/CANCEL…
- User Interface/Control System TestAfter activating Service Diagnostic Mode, press and release the 1st button used to activate Service…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Amana furnace models
76,000+ service documents · 19,000+ error codes · 100+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax