Tech Tip
- Instruction Sheet - 854179812 pg
MyPros+ Max
Diagnose your Amana CRRL-8TD/P75593-4M.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (56)
CodeMeaning
d1Blocked coin 1 or coin drop UI control circuit failure (coin recognition and…d2Voltage detected below 90 VAC for 8 seconds.d3Blocked coin 2 or coin drop UI control circuit failure (coin recognition and…d4Not receiving communications from installed debit card reader in Enhanced…E1Thermistor is open (open circuit detected).E2Thermistor has shorted (short circuit detected).E3User interface keyswitch or software mismatch between the control…F-01Primary control failure.F-02Stuck button or user interface mismatch (only appears in diagnostic test mode).F-22Exhaust thermistor is open.F-23Exhaust thermistor has shorted.F-26Motor drive system failure.F-28Moisture sensor strip is open (only appears in diagnostic test mode).F-29Moisture sensor strip has shorted (only appears in diagnostic test mode).F:01Primary control failure.F:02Stuck button or user interface mismatch (only appears in diagnostic test mode).F:22Outlet thermistor is open.F:23Outlet thermistor has shorted.F:24Inlet thermistor is open (only appears in diagnostic test mode).F:25Inlet thermistor is shorted (only appears in diagnostic test mode).F:26Motor drive system failure.F:28Moisture sensor strip is open (only appears in diagnostic test mode).F:29Moisture sensor strip has shorted (only appears in diagnostic test mode).F:30Restricted airflow condition exists (only appears in diagnostic test mode).F:70No communication between the machine control and the console electronics.F:71No communication between the machine control and the console electronics.F:72Console electronics failure.F:73Console electronics failure.F:74Console electronics failure.F:75Console electronics failure.View all 56 error codes
F:76Console electronics failure.F:77Console electronics failure.F:78Console electronics failure.F1Dryer motor control circuit error (cycles and price display disabled until…F1E1Primary control failure.F2Exhaust thermistor open, temperature drops below 18°F (>50 kΩ) for 1 minute in…F2E1Stuck button or user interface mismatchF3Exhaust thermistor shorted, temperature above 250°F (<500Ω) for 1 minute in Run…F3E1Exhaust thermistor is open.F3E2Exhaust thermistor has shorted.F3E3Inlet thermistor is open; temperature drops below 18°F (>245k ohms).F3E4Inlet thermistor has shorted; temperature above 391°F (<328 ohms).F3E5Inlet and exhaust thermistors are open; will occur if P14 connector is not…F3E6Moisture sensor strip is openF3E7Moisture sensor strip has shortedF4UI is not receiving communications from CCU (cycles and price display disabled…F4E1No voltage detected at the heater relay; only appears in Diagnostic Test Mode.F4E3Restricted/low air flow that may affect dryer performance.F4E4Low L2 voltage (less than 50V) detected at the CCU.F5CCU is not receiving communications from UI (cycles and price display disabled…F6UI Microprocessor is not able to read or verify EEPROM (cycles and price…F6E1Communication errorF6E2Communication errorF7UI EEPROM memory is a CRC failure (cycles and price display disabled until…L2Low L2 voltage (less than 50V) detected at the CCU.PFPower failure occurred while the dryer was running.
Service modes (23)
- Adjusting Customer-Focused Drying Modes (CF1/CF2/CF3)1
- Console Diagnostics (within Diagnostic Test Mode)["Enter Diagnostic Test Mode as described above.","Press each button or turn the cycle selector to…
- Customer-Focused Drying Mode Adjustment1
- Customer-Focused Dryness Level Adjustment["In standby mode (dryer plugged in but not powered up), press and hold the DRYNESS LEVEL button…
- diagnostic["Set door to open position","Set temperature switch to Air Only","Set End of Cycle Signal switch…
- Diagnostic Test Mode1
- Diagnostic: Door Switch (within Diagnostic Test Mode)["Enter Diagnostic Test Mode.","Open the dryer door
- Diagnostic: Moisture Sensor (within Diagnostic Test Mode)["Enter Diagnostic Test Mode.","Locate two metal strips on the face of the lint screen…
- Displaying Inlet Air Flow DiagnosticAfter all saved fault codes have been displayed in diagnostic test mode, press the Wrinkle Guard…
- Displaying Line Voltage DiagnosticAfter all saved fault codes have been displayed in diagnostic test mode, press the Cycle Signal…
- Dryness Adjust Mode (TEST #4a)1. Activate the diagnostic test mode and advance past saved fault codes. 2. Press and hold the…
- Factory Test["Open the door","Set Temperature switch to AIR ONLY","Set Signal switch to LOUDER","Set Timer to…
- help["Enter set-up mode.","Navigate to special pricing option 2.XX.","Press the COTTON/WHITES button to…
- Install Diagnostics["Activate Service Diagnostic Mode first.","Press and release the 2nd button used to activate…
- less_dry_test["Begin with a fully assembled, empty dryer with clean lint screen connected to a known good power…
- Loads Test Mode["Ensure dryer is in standby mode (plugged in with all indicators off).","Within 5 seconds: Press…
- Manual Load Test1. Ensure dryer is in standby mode (plugged in with all indicators off, or with only the Clothes…
- Service Diagnostic Mode1
- Service Diagnostic Test Mode1
- setup["Method 1 (9150 models)
- Software Version Display["Activate Service Diagnostic Mode first.","Press and hold the 2nd button used to activate Service…
- User Interface Test["First activate the Service Diagnostic Mode.","Press and release the 1st button used to activate…
- User Interface/Control System TestFrom within Service Diagnostic mode, press and release the 1st button used to enter Service…
Full entry steps, exit procedures, and test sequences are available in Max.