Model reference
Amana R-2/P71306-1M
Microwave
7 documents62 error codes21 service modes
Available documentation
Tech Sheet
- Tech Sheet2 pg
Service Manual
- KitchenAid Diamond Blender Service/Repair Manual21 pg
Tech Tip
- Instruction Sheet - 857665312 pg
- Instruction Sheet - 39797188 pg
- Instruction Sheet - 39797208 pg
- Instruction Sheet - 3979706 - Rev A8 pg
- Instruction Sheet - 39800568 pg
MyPros+ Max
Diagnose your Amana R-2/P71306-1M.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (62)
CodeMeaning
:Flashing colon indicates a power failure has occurred.CAAverage current limit tripCECommunications errorCIInstantaneous current limit tripd13Coin 2 error; coin 2 detector detects that the coin slot is obstructed for 8…d9Low voltage detection error; input voltage detected below 90 VAC for 8 seconds.ErProcessor reset errorF01Communication error in the Central Control Unit (CCU); the pump drive in the…F0E0No error(s) foundF11Motor Control Unit (MCU) malfunction, possibly due to repeated under-voltage or…F1E0Internal failureF1E1Motor relay stuck on, indicates an ACU problem.F1E3Incorrect controller installed; ACU and/or User Interface part numbers do not…F1E4Microwave relay failure.F1E5ACU parameter file missing; parameter memory invalid.F20No water entry detected; first pressure switch level not reached within 6…F21Excessive drain time; drain operation exceeds 8 minutes without reaching the…F22Door lock error; after multiple lock attempts and customer intervention, the…F24Water temperature sensor value out of range (-5°C to 103°C / 23°F to 217°F).F25Tachometer error; the MCU is unable to correctly detect motor speed, causing…F26Door switch error; the door switch circuit remains open for 5 seconds while the…F27Overflow condition; the overflow contact of the pressure switch is closed for…F28Communication failure between Central Control Unit (CCU) and Motor Control Unit…F29Door unlock error; after 6 attempts the door does not unlock.F2E0Keypad disconnected.F2E1User Interface stuck button (depressed for over 20 seconds); only appears in…F2E3Keypad hardware failure.F2E4UI software errorF2E5UI software errorF34Load detected in washer during the Clean Washer cycle.View all 62 error codes
F3E0Oven sensor open or shorted.F3E1Exhaust thermistor is open or shorted; open if temperature drops below 18°F…F3E2Moisture sensor strip is open or shorted; only appears in service diagnostic…F3E3Meat probe shorted.F3E6Moisture sensor strip is open; this fault code will ONLY appear when in the…F3E7Moisture sensor strip has shorted; this fault code will ONLY appear when in the…F4E1Heater 1 failure or connector problem; no voltage detected at the heater relay.F4E4L2 line voltage error; low L2 voltage (less than 50V) detected at the ACU.F5E0Door and latch switch do not agree.F5E1Door latch not operating.F6E0Lost communication.F6E1Cook oven over temperature.F6E2Communication errorF6E3Communication errorF6E4User interface / appliance manager mismatch.F6E5Cavity size is incorrect.F6E6Lost communication between user interface (UI) and appliance manager 1 (AM1).F70Communication failure between Central Control Unit (CCU) and User Interface…F8E0Low fan speed underspeed.F8E1Low fan speed overspeed.F8E2High fan speed underspeed.F8E3High fan speed overspeed.F8E5Exhaust air temperature detection failure.FLOverfill conditionL2Low L2 voltage (less than 50V) detected at the CCU.LdLong drainLFLong fillLSLid switch errorobOff balancePFA power failure occurred while the dryer was running.SLSuds lockSrStuck relay
Service modes (21)
- ADC Test Mode - First Method["Turn the thermostat off for 15 seconds","Turn the thermostat on for 5 seconds","Turn the…
- ADC Test Mode - Second Method["Disconnect the refrigerator/freezer from the wall outlet for at least 30 seconds","Turn the…
- Automatic Service DiagnosticsWith control OFF, press PREWASH OPTIONS → WASH TIME → PREWASH OPTIONS → WASH TIME within 5 seconds.
- Customer-Focused Drying Mode Adjustment["Ensure dryer is in standby mode (plugged in with all indicators off, or with only the DONE…
- Customer-Focused Dryness Level Adjustment["In standby mode (dryer plugged in but not powered up), press and hold the DRYNESS or DRY LEVEL…
- diagnostic1. Plug in microwave oven or reconnect power. In idle mode, close the door, turn off hood light and…
- Diagnostic Mode (Blink Mode)["Enter Setup/Programming mode first.","Press and hold the COLD button for 2 seconds when setup…
- Diagnostics Mode["Press three different keys in sequence three times in a row within 8 seconds (example
- Help Mode["Enter Setup/Programming mode.","Press WARM button until setup code 2.XX is displayed.","Press HOT…
- Key Activation & Encoder Test["Enter Service Diagnostic Mode first.","Press and release the 1st button used to activate Service…
- Keypad and LED TestWith control OFF, press SET DELAY TIME → END OF CYCLE SIGNAL → SET DELAY TIME → END OF CYCLE SIGNAL…
- Nutate and Recirculate TestWith control OFF, press SET DELAY TIME → END OF CYCLE SIGNAL → SET DELAY TIME → END OF CYCLE SIGNAL…
- Service Access Code Entry["Door must be open if washer is not in fault mode.","Press the upper left button.","Press the…
- Service Diagnostic Mode["Ensure dryer is in standby mode (plugged in with all indicators off).","Select any three buttons…
- Service Test Mode["Enter Service Diagnostic Mode first.","Press and release the 2nd button used to activate Service…
- Setup/Programming Mode (Model 9050)["Insert key into access door, turn and lift to remove the access door."]
- Setup/Programming Mode (Model 9060 via connector)["Disconnect power from the washer.","Open the console and disconnect connector AA1.","Close the…
- Software Version Display["Enter Service Diagnostic Mode first.","Press and hold the 2nd button used to activate Service…
- Spin and Drain TestWith control OFF, press SET DELAY TIME → END OF CYCLE SIGNAL → SET DELAY TIME → END OF CYCLE SIGNAL…
- User Interface/Control System Test["First activate Service Diagnostic Mode (see above).","Press and release the 1st button used to…
- Water Inlet and Dispenser Valve Operating PS TestWith control OFF, press SET DELAY TIME → END OF CYCLE SIGNAL → SET DELAY TIME → END OF CYCLE SIGNAL…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Amana microwave models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass