Model reference
Amana RC-10B-DD
Microwave
13 documents66 error codes7 service modes
Available documentation
Tech Sheet
- Tech Sheet2 pg
- Tech Sheet - W11790220 - Rev A2 pg
- Tech Sheet - W11777475 - Rev A2 pg
- Tech Sheet - W11604694 - Rev A2 pg
- Instruction Sheet - TECH SHEET20 pg
- Tech Sheet - W11397131 - Rev A2 pg
- Tech Sheet - W11399175 - Rev A2 pg
- Tech Sheet - W1037157520 pg
- Tech Sheet - W11399233 - Rev A2 pg
- Tech Sheet - W10419696 - Rev A28 pg
- Commercial Microwave Technical Information10 pg
- Tech Sheet16 pg
Tech Tip
- Instruction Sheet - 818476320 pg
MyPros+ Max
Diagnose your Amana RC-10B-DD.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (66)
CodeMeaning
-F2-Keyboard (membrane switch) failure.-F3H-Humidity sensor failure.-F3T-Temperature sensor failure.-F7-Power to magnetron interrupted.:Flashing colon indicates a power failure has occurred.F1.E1Relay Control Board defective.F1E0EEPROM Communication ErrorF1E1Upper RTD UncalibratedF1E2Lower RTD UncalibratedF1E5Sensor Usage Out of RangeF1E7PCB Thermistor Open or ShortedF1E9WIDE Queue FullF1EASecondary ACU Over Temperature.F1EBKey is continuously closed/activated.F2Touch panel failure.F2.H1Hood/light switch stuck.F2.H2Hood/light switch error.F2.Q1User interface board (UIB) is not reading keypad inputs.F2E0Keypad DisconnectedF2E1Stuck KeypadF2E2Cancel or Off Keypad ErrorF2E4Main oven temp sensor open/shorted.F3.H1Humidity sensor failure.F3.T1UIB (user interface board) thermistor failure.F3.T2FC (forced convection) thermistor failure.F3.T4Magnetron thermistor failure.F3E0Main Sensor Open or Shorted (Upper)F3E1Main Sensor Open or Shorted (Lower)F3E3Meat probe connector jack or meat probe shorted.F3E9Microwave Cavity Temperature Sensor open/shorted.View all 66 error codes
F3HHumidity sensor failure.F4E1Low Fan Speed UnderspeedF4E2Microwave Humidity Sensor out of Range.F4E4Microwave Oven Humidity Sensor Open or ShortedF4E7Main Door and Latch Switches Do Not Agree.F5E0Door and Latch Switches Do Not AgreeF5E1Latch Not OperatingF5E3Door and latch switch do not agree (lower oven).F5E4Latch not operating (lower oven).F6MW relay failure (Relay 4903 on Relay Board).F6E0Lost Communication with MicrowaveF6E1Over Temperature CookF6E2Over Temperature CleanF6E3Over temperature (lower oven).F6E4User interface/Appliance manager state status mismatch.F6E6Oven appliance managerF6E9Oven appliance managerF7Power to magnetron interrupted.F7E5Main Cooling Fan Blocked.F7E6Main Cooling Fan Blocked.F8E0Microwave Oven Magnetron Thermistor Open or ShortedF8E1Low Fan Speed OverspeedF8E2High Fan Speed UnderspeedF8E3High Fan Speed OverspeedF9Relay Control Board communications error.F9.QTouch communication error.F9E0MiswiredFBE1Main cavity over temperature condition.FBEAACU Fault (Secondary ACU failure).FBEBMicrowave ACU Over Temperature.FCE1Model/Serial number not programmed.FCE2Model/Serial number do not match.FCE3Wi-Fi radio fault.FEE6Main cavity bake element fault.FEE7Main cavity broil element fault.No DisplayControl is blank
Service modes (7)
- Diagnostic ModePress CANCEL>CANCEL>START or OFF>OFF>ON within 5 seconds.
- Diagnostics mode["Single Ovens
- Self-Diagnostic Test Mode (Touch Panel and Microcomputer Board Test)["Depress the 'Cancel OFF' button while opening the door.","While still depressing the 'Cancel OFF'…
- Service Diagnostic Mode["Press any sequence of three keys (excluding 'warm zone' and 'cancel').","Repeat the same…
- Test Mode (Touch Panel and Relay Control Board Tests)["1
- Touch Panel and PCBA Self-Diagnostic Test Mode["1
- Touch Panel Test Mode["1
Full entry steps, exit procedures, and test sequences are available in Max.